A Laboratory Comparison of a New Arthroscopic Transosseous Rotator Cuff Repair to a Double Row Transosseous Equivalent Rotator Cuff Repair Using Suture Anchors

被引:0
作者
Kummer, Frederick J. [1 ]
Hahn, Michael [1 ]
Day, Michael [1 ]
Meislin, Robert J. [1 ]
Jazrawi, Laith M. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthoped, 301 East 17th St, New York, NY 10003 USA
来源
BULLETIN OF THE HOSPITAL FOR JOINT DISEASES | 2013年 / 71卷 / 02期
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Because current instrumentation makes it possible to perform an arthroscopic transosseous rotator cuff repair, we performed a biomechanical comparison of a double-row transosseous equivalent rotator cuff repair using suture anchors to an arthroscopic, transosseous rotator cuff repair to determine if they provided similar fixation stability. Methods: Six pairs of shoulders were used. One of each pair had a standard double row, transosseous equivalent arthroscopic rotator cuff repair using a suture-bridge technique with suture anchors, and the other had an arthroscopic transosseous repair using an Xbox technique. The repairs were cycled at 150 N for 10,000 cycles with movement of the lateral cuff edge recorded and then tested to failure. Results: The total cuff edge displacement at 10,000 cycles in the anchor group (transosseous equivalent repair) was 7.9 mm and 6.3 mm for the bone tunnel group (transosseous repair); these were not significantly different (p = 0.19). The anchor group failed at an average of 309 N and the bone tunnel group at an average of 339 N (p = 0.22). Discussion: Biomechanical testing suggests that arthroscopic, transosseous rotator cuff repair using a Xbox suture configuration is similar in strength and stability to an arthroscopic transosseous equivalent suture-bridge repair. Both techniques demonstrated difficulty in maintaining the lateral position of the tendon.
引用
收藏
页码:128 / 131
页数:4
相关论文
共 10 条
[1]   Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques [J].
Ahmad, CS ;
Stewart, AM ;
Izquierdo, R ;
Bigliani, LU .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (11) :1667-1671
[2]   A Biomechanical Comparison of Transosseous-Suture Anchor and Suture Bridge Rotator Cuff Repairs in Cadavers [J].
Bisson, Leslie J. ;
Manohar, Leslie M. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (10) :1991-1995
[3]   Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[4]   Single-row Versus Double-row Rotator Cuff Repair: Techniques and Outcomes [J].
Dines, Joshua S. ;
Bedi, Asheesh ;
ElAttrache, Neal S. ;
Dines, David M. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2010, 18 (02) :83-93
[5]   What's new in shoulder and elbow surgery [J].
Gartsman, GM ;
Hasan, SS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) :230-243
[6]   Cyclic loading of rotator cuff repairs: A comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures [J].
Goradia, VK ;
Mullen, DJ ;
Boucher, HR ;
Parks, BG ;
O'Donnell, JB .
ARTHROSCOPY, 2001, 17 (04) :360-364
[7]   A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair [J].
Smith, Christopher D. ;
Alexander, Susan ;
Hill, Adam M. ;
Huijsmans, Pol E. ;
Bull, Anthony M. J. ;
Amis, Andrew A. ;
De Beer, Joe F. ;
Wallace, Andrew L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (11) :2425-2431
[8]   Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique [J].
Tocci, Stephen L. ;
Tashjian, Robert Z. ;
Leventhal, Evan ;
Spenciner, David B. ;
Green, Andrew ;
Fleming, Braden C. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (05) :808-814
[9]   Rotator cuff repair: An analysis of utility scores and cost-effectiveness [J].
Vitale, Mark A. ;
Vitale, Michael G. ;
Zivin, Joshua G. ;
Braman, Jonathan P. ;
Bigliani, Louis U. ;
Flatow, Evan L. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) :181-187
[10]   Rotator cuff repair - A biomechanical comparison of three techniques [J].
Waltrip, RL ;
Zheng, N ;
Dugas, JR ;
Andrews, JR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (04) :493-497