THE AIR TEST AS A CLINICALLY USEFUL INDICATOR OF INTRAVENOUSLY PLACED EPIDURAL CATHETERS

被引:43
作者
LEIGHTON, BL
NORRIS, MC
DESIMONE, CA
ROSKO, T
GROSS, JB
机构
[1] UNIV CONNECTICUT,CTR HLTH,DEPT ANESTHESIOL,263 FARMINGTON AVE,FARMINGTON,CT 06032
[2] THOMAS JEFFERSON UNIV,DEPT ANESTHESIOL,PHILADELPHIA,PA 19107
关键词
anesthesia; obstetric; anesthetic techniques: epidural; continuous; monitoring equipment: Doppler ultrasound; test doses; epidural;
D O I
10.1097/00000542-199010000-00004
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The authors performed a clinical trial in 313 patients in labor to determine the safety and efficacy of an air test for unintentional intravenous placement of epidural catheters. Following routine aspiration for blood and cerebrospinal fluid, 1 ml of air was injected through each epidural catheter while heart tones were continually monitored with a Doppler ultrasound probe placed over the maternal precordium. In 281 patients, Doppler heart tones did not change following air injection (negative air test). All but eight of these patients developed an adequate level of analgesia following anesthetic administration, and no patients with negative air tests developed signs or symptoms of local anesthetic toxicity (false-negative rate, 0%; 95% confidence limits, 0.0-1.1%). Doppler heart tone changes followed air injection in 22 cases (positive air test). In 16 of these, intravenous catheter position was subsequently shown by aspiration of blood from the catheter or by the use of test doses consisting of local anesthetics with or without epinephrine. In six cases, adequate levels of analgesia developed despite a positive air test (false-positive rate, 2%; 95% confidence limit, 0.7-4.3%). None of the 303 patients receiving the air test developed any complications attributable to the injection of air (95% confidence limits, 0.0-1.0%). The authors conclude that air, with precordial Doppler detection, is a safe and effective test for identifying intravenously located epidural catheters.
引用
收藏
页码:610 / 613
页数:4
相关论文
共 6 条
  • [1] EPIDURAL-ANESTHESIA FOR POSTPARTUM TUBAL-LIGATION USING EPIDURAL CATHETERS PLACED DURING LABOR
    VINCENT, RD
    REID, RW
    JOURNAL OF CLINICAL ANESTHESIA, 1993, 5 (04) : 289 - 291
  • [2] The efficacy of surgically placed epidural catheters for analgesia after posterior spinal surgery
    Turner, A
    Lee, J
    Mitchell, R
    Berman, J
    Edge, G
    Fennelly, M
    ANAESTHESIA, 2000, 55 (04) : 370 - 373
  • [3] An observational cohort study of the meniscus test to detect intravascular epidural catheters in pregnant women
    Servin, M. N.
    Mhyre, J. M.
    Greenfield, M. L. V. H.
    Polley, L. S.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2009, 18 (03) : 215 - 220
  • [4] PARESTHESIA WITH LUMBAR EPIDURAL CATHETERS - A COMPARISON OF AIR AND SALINE IN A LOSS-OF-RESISTANCE TECHNIQUE
    SARNA, MC
    SMITH, I
    JAMES, JM
    ANAESTHESIA, 1990, 45 (12) : 1077 - 1079
  • [5] Epidural spread of iohexol following the use of air or saline in the 'loss of resistance' test
    Iseri, Toshie
    Nishimura, Ryohei
    Nagahama, Shotaro
    Mochizuki, Manabu
    Nakagawa, Takayuki
    Fujimoto, Yuka
    Zhang, Di
    Sasaki, Nobuo
    VETERINARY ANAESTHESIA AND ANALGESIA, 2010, 37 (06) : 526 - 530
  • [6] The Efficacy of Perfusion Index as an Indicator for Intravascular Injection of Epinephrine-Containing Epidural Test Dose in Propofol-Anesthetized Adults
    Mowafi, Hany A.
    Ismail, Salah A.
    Shafi, Mohammed A.
    Al-Ghamdi, AbdulMolisiri A.
    ANESTHESIA AND ANALGESIA, 2009, 108 (02) : 549 - 553