HARD X-RAY SPUTTERED-SLICED PHASE ZONE PLATES

被引:25
|
作者
BIONTA, RM [1 ]
SKULINA, KM [1 ]
WEINBERG, J [1 ]
机构
[1] UNIV ARIZONA,TUCSON,AZ 85726
关键词
Aluminum - Copper - Focusing - Image analysis - Mathematical models - Monte Carlo methods - Optical variables measurement - Phase shift - Photons - Radiography - Refractive index - Thickness measurement;
D O I
10.1063/1.110968
中图分类号
O59 [应用物理学];
学科分类号
摘要
Al/Cu sputtered-sliced phase zone plates, designed to operate with a focal length of 18 cm at 8.05 keV, were tested at the Stanford Synchrotron Radiation Laboratory. First-, second-, and third-order peaks are measured, along with a defocused condition. The first-order focusing efficiencies ranged from 13% to 19% for the two lenses presented here. Monte Carlo simulations are compared to the data.
引用
收藏
页码:945 / 947
页数:3
相关论文
共 50 条
  • [1] Fabrication of a hard x-ray sputtered-sliced Fresnel phase zone plate
    Kamijo, N
    Tamura, S
    Suzuki, Y
    Handa, K
    Takeuchi, A
    Yamamoto, S
    Ando, M
    Ohsumi, K
    Kihara, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 14 - 16
  • [2] Sputtered-sliced fabrication of kinoform zone plate for hard X-ray focusing
    Yasumoto, M
    Tamura, S
    Kamijo, N
    Suzuki, Y
    Awaji, M
    Takeuchi, A
    Takano, H
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 189 - 192
  • [3] FABRICATION AND TESTING OF HARD X-RAY SPUTTERED-SLICED ZONE-PLATE
    KAMIJO, N
    TAMURA, S
    SUZUKI, Y
    KIHARA, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2132 - 2134
  • [4] Hard X-ray microbeam experiments with a sputtered-sliced Fresnel zone plate and its applications
    Kamijo, N
    Suzuki, Y
    Awaji, M
    Takeuchi, A
    Takano, H
    Ninomiya, T
    Tamura, S
    Yasumoto, M
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 182 - 186
  • [5] Microbeam of 200 keV X-ray with Sputtered-Sliced Zone Plate
    Kamijo, Nagao
    Suzuki, Yoshio
    Takeuchi, Akihisa
    Itou, Masayoshi
    Tamura, Shigeharu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (01)
  • [6] STATUS OF THE SPUTTERED SLICED ZONE PLATES FOR X-RAY MICROSCOPY
    RUDOLPH, D
    NIEMANN, B
    SCHMAHL, G
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 316 : 103 - 105
  • [7] Sliced linear zone plates for hard X-ray radiation
    I. A. Artyukov
    V. A. Burtsev
    A. V. Vinogradov
    A. Yu. Devizenko
    N. V. Kalinin
    I. A. Kopylets
    V. V. Kondratenko
    V. E. Pukha
    B. A. Savitskii
    R. M. Feshchenko
    Technical Physics, 2012, 57 : 1283 - 1288
  • [8] Sliced linear zone plates for hard X-ray radiation
    Artyukov, I. A.
    Burtsev, V. A.
    Vinogradov, A. V.
    Devizenko, A. Yu.
    Kalinin, N. V.
    Kopylets, I. A.
    Kondratenko, V. V.
    Pukha, V. E.
    Savitskii, B. A.
    Feshchenko, R. M.
    TECHNICAL PHYSICS, 2012, 57 (09) : 1283 - 1288
  • [9] Microbeam of 100 keV x ray with a sputtered-sliced Fresnel zone plate
    Kamijo, N
    Suzuki, Y
    Takano, H
    Tamura, S
    Yasumoto, M
    Takeuchi, A
    Awaji, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (12): : 5101 - 5104
  • [10] X-ray microbeam with sputtered-sliced Fresnel zone plate at Spring-8 undulator beamline
    Suzuki, Y
    Awaji, M
    Kohmura, Y
    Takeuchi, A
    Kamijo, N
    Tamura, S
    Handa, K
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 535 - 538