The influence of NaCl and Na2SO4 as supporting electrolyte on analysis of Lead(II) in seawater by stripping voltammetry using hanging mercury drop electrode

被引:0
作者
Khasanah, Miratul [1 ]
Darmokusumo, Handoko [1 ]
Rochmawati [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Chem Dept, Surabaya 60115, Indonesia
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2014年 / 10卷 / 03期
关键词
lead (II); sea water; supporting electrolyte; hanging mercury drop; stripping voltammetry;
D O I
10.11113/mjfas.v10n3.263
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The influence of NaCl and Na2SO4 as supporting electrolyte on lead (II) analysis in seawater by stripping voltammetry was studied. The instrumental parameters obtained in this recent study were deposition potential -1000 mV, deposition time 150 s, and stirring rate 2000 rpm. The concentration of supporting electrolyte used was 300 mu g/L NaCl and 1800 mu g/L Na2SO4. The detection limit and sensitivity of the method using NaCl as supporting electrolyte were 0.1483 mu g/L and 29.207 nA L/mu g, respectively. The precision in the range of 1-5 mu g/L of lead (II) was 1.01-6.37%. Lead (II) analysis voltammetrically using Na2SO4 as supporting electrolyte resulted in the analytical performance as follow: detection limit of 0.5498 mu g/L, sensitivity of 8.037 nA L/mu g, precision of 0.34-5.9 %. Analysis of lead (II) by stripping voltammetry using NaCl and Na2SO4 as supporting electrolyte resulted in recovery of 99.90 % (n= 3) and 104.2 % (n=3), respectively. The presence of both NaCl and Na2SO4 slightly amplified the lead (II) current signal.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 1980, ELECTROCHEMICAL METH
[2]  
Castro P., 2007, MCGRAW HILL HIGHER E
[3]   Quantitative analysis of metals in soil using X-ray fluorescence [J].
dos Anjos, MJ ;
Lopes, RT ;
de Jesus, EFO ;
Assis, JT ;
Cesareo, R ;
Barradas, CAA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1189-1194
[4]  
Hines J., 1987, J ENVIRON EDUC, V18, P1, DOI DOI 10.1080/00958964.1987.9943482
[5]  
Jr J. Workman, 2006, SPECTROSCOPY, V21, P18
[6]  
KUMAMARU T, 1987, ANAL SCI, V3, P161
[7]   Voltammetric trace metal determinations by cathodic and anodic stripping voltammetry in environmental matrices in the presence of mutual interference [J].
Locatelli, C ;
Torsi, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 509 (01) :80-89
[8]  
Popo I., 2006, THESIS, P25
[9]   SALICYLIC-ACID FUNCTIONALIZED POLYSTYRENE SORBENT AMBERLITE XAD-2 - SYNTHESIS AND APPLICATIONS AS A PRECONCENTRATOR IN THE DETERMINATION OF ZINC(II) AND LEAD(II) BY USING ATOMIC-ABSORPTION SPECTROMETRY [J].
SAXENA, R ;
SINGH, AK ;
RATHORE, DPS .
ANALYST, 1995, 120 (02) :403-405
[10]   The determination of metals (antimony, bismuth, lead, cadmium, mercury, palladium, platinum, tellurium, thallium, tin and tungsten) in urine samples by inductively coupled plasma-mass spectrometry [J].
Schramel, P ;
Wendler, I ;
Angerer, J .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1997, 69 (03) :219-223