ELEMENTAL SPECIATION WITH LIQUID-CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA ISOTOPE-DILUTION MASS-SPECTROMETRY

被引:126
作者
HEUMANN, KG
ROTTMANN, L
VOGL, J
机构
[1] Univ of Regensburg, Regensburg, Germany
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY COUPLING; ISOTOPE DILUTION MASS SPECTROMETRY; IODINE SPECIES; HEAVY METAL COMPLEXES; AQUATIC SYSTEMS;
D O I
10.1039/ja9940901351
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the determination of elemental species, which normally exist at low concentrations in the environment, coupling of liquid chromatographic systems with inductively coupled plasma mass spectrometry (ICP-MS) is a powerful method with respect to detection limit. However, accurate results are still a problem in trace analyses but can be obtained by the application of isotope dilution mass spectrometry (IDMS). The developed LC-ICP-IDMS system consists of a high-performance liquid chromatography pump, a sample injection valve, a separation column (different types of chromatographic separation systems, e.g., ion or size-exclusion chromatography, were used depending on the separation problem), a non-destructive detector (e.g. a UV detector) for simultaneous determination of organic substances, and an element-specific ICP mass spectrometer. Isotope dilution is carried out by adding an isotopically enriched species-specific spike solution to the sample prior to the separation step in the case of the determination of well-defined species, or by continuous on-line introduction of a species-unspecific spike solution in the case of species with unkown composition and structure. The species-specific spiking method is demonstrated for the determination of iodide and iodate in mineral water using an ion chromatographic separation column. For example, iodate concentrations in the range of 0.5-20 ng ml(-1) could be determined with relative standard deviations of about 2%. The species-unspecific spiking mode is used to determine heavy metal complexes with humic substances at a level of about 1 ng ml(-1) as well as organo-iodine species in the concentration range 0.7-1.4 ng ml(-1) in natural water systems. The accuracy of speciation could be verified by comparing the total element concentration with the sum of the different elemental species.
引用
收藏
页码:1351 / 1355
页数:5
相关论文
共 15 条
[1]   LEAD SPECIATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
ALRASHDAN, A ;
VELA, NP ;
CARUSO, JA ;
HEITKEMPER, DT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :551-555
[2]   DETERMINATION OF COPPER, MOLYBDENUM AND SELENIUM IN BIOLOGICAL REFERENCE MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BUCKLEY, WT ;
IHNAT, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4) :217-220
[3]   APPLICATION OF HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE INVESTIGATION OF CADMIUM SPECIATION IN PIG-KIDNEY FOLLOWING COOKING AND INVITRO GASTROINTESTINAL DIGESTION [J].
CREWS, HM ;
DEAN, JR ;
EBDON, L ;
MASSEY, RC .
ANALYST, 1989, 114 (08) :895-899
[4]   STABLE ISOTOPE-DILUTION ANALYSIS OF HYDROLOGIC SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GARBARINO, JR ;
TAYLOR, HE .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1568-1575
[5]   DETERMINATION OF LEAD AND OTHER TRACE-ELEMENT SPECIES IN BLOOD BY SIZE EXCLUSION CHROMATOGRAPHY AND INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GERCKEN, B ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :283-287
[6]   SEPARATION OF 7 ARSENIC COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE DETECTION BY HYDROGEN ARGON FLAME ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HANSEN, SH ;
LARSEN, EH ;
PRITZL, G ;
CORNETT, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :629-634
[7]  
Heumann K.G., 1988, INORGANIC MASS SPECT, P301
[8]  
HEUMANN KG, 1990, NATO ASI SERIES G, V23, P153
[9]  
LARSEN EH, 1994, 1994 WINT C PLASM SP, P67
[10]   METALLOPROTEIN SEPARATION AND ANALYSIS BY DIRECTLY COUPLED SIZE EXCLUSION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA MASS-SPECTROSCOPY [J].
MASON, AZ ;
STORMS, SD ;
JENKINS, KD .