UNSATISFACTORY RESULTS WITH A CERAMIC TOTAL HIP-PROSTHESIS

被引:102
|
作者
MAHONEY, OM
DIMON, JH
机构
[1] PIEDMONT HOSP, PEACHTREE ORTHOPAED CLIN, ATLANTA, GA 30367 USA
[2] MED COLL GEORGIA HOSP, ORTHOPAED SECT, AUGUSTA, GA USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 1990年 / 72A卷 / 05期
关键词
D O I
10.2106/00004623-199072050-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the results of forty-two total hip replacements that had been done with the self-locking Autophor ceramic total hip prosthesis in thirty-four patients. The patients ranged in age from twenty-five to sixty-seven years (average, forty-eight years). The diagnoses were avascular necrosis (eight patients), degenerative arthritis (nineteen patients), ankylosing spondylitis (one patient), post-traumatic arthritis (two patients), and rheumatoid arthritis (four patients). Seven procedures were revisions: five, of a loose cemented total hip prosthesis and two, of a loose noncemented endoprosthesis. No revision was done for infection. The length of follow-up ranged from twenty-seven to sixty-six months (average, fifty-one months). The patients were evaluated by physical examination, serial radiographs, and questionnaires. The hips were rated with the modified Harris hip score. At the time of follow-up, eleven of the twenty-seven patients who had had a primary hip replacement complained of at least moderate pain that limited activities; however, only three patients had to have a revision. The femoral components had a notable tendency to subside more than five millimeters, and in fifteen hips there was radiographic evidence of progressive loosening. Our experience with the self-locking Autophor ceramic total hip prosthesis has been disappointing. We no longer use it.
引用
收藏
页码:663 / 671
页数:9
相关论文
共 50 条
  • [1] THE CERAMIC TOTAL HIP-PROSTHESIS (TYPE MITTELMEIER)
    FEITH, R
    MEGENS, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (04): : 390 - 390
  • [2] FRACTURED CERAMIC HEAD AFTER TOTAL HIP-PROSTHESIS
    TESCH, M
    BREWKA, N
    TAUSCH, W
    ZENTRALBLATT FUR CHIRURGIE, 1991, 116 (03): : 193 - 195
  • [3] RESULTS OF THE LORD CEMENTLESS TOTAL HIP-PROSTHESIS
    SOEM, OI
    CHRISTENSEN, A
    REIKERAS, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 341 - 341
  • [4] THE PRETORIA CERAMIC HIP-PROSTHESIS
    GROBBELAAR, CJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03): : 502 - 502
  • [5] A CEMENTLESS SYSTEM OF TOTAL HIP-PROSTHESIS - EXPERIMENTAL STUDIES ON TOTAL HIP-PROSTHESIS IN DOGS
    ITAMI, Y
    AKAMATSU, N
    TOMITA, Y
    NAGAI, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1982, 100 (03) : 183 - 189
  • [6] ETIOLOGY AND TREATMENT OF LOOSENING OF THE CERAMIC CUPS IN TOTAL HIP-PROSTHESIS
    SEDEL, L
    CHRISTEL, P
    HERMAN, S
    WITVOET, J
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1985, 71 : 29 - 32
  • [7] PRIMARY RESULTS OF THE LORD CEMENTLESS TOTAL HIP-PROSTHESIS
    STROMSOE, K
    OSLEBY, P
    ALHO, A
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (03): : 273 - 273
  • [8] THE INFECTED TOTAL HIP-PROSTHESIS
    SCHNEIDER, R
    ORTHOPADE, 1989, 18 (06): : 527 - 532
  • [9] TOTAL HIP-PROSTHESIS AND SPORT
    STEINBRUCK, K
    GARTNER, BM
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1979, 121 (39): : 1247 - 1250
  • [10] 10-YEAR SURVIVORSHIP OF CEMENTED CERAMIC CERAMIC TOTAL HIP-PROSTHESIS
    NIZARD, RS
    SEDEL, L
    CHRISTEL, P
    MEUNIER, A
    SOUDRY, M
    WITVOET, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (282) : 53 - 63