摘要
A description is given of a low temperature ( minus 160 degree C) irradiation cell for a particle accelerator. This cell also allows the study of irradiated samples by infrared spectroscopy at minus 145 degree C, without contact with air. It is shown how this device makes possible the study of reactions of the first kind between ions and matter. In the case of solid-state nuclear track detectors, it can thus be understood why cellulose diacetate is a poor detector compared with cellulose triacetate.