THE EFFICACY OF ROUTINE CENTRAL VENOUS MONITORING IN MAJOR HEAD AND NECK-SURGERY - A RETROSPECTIVE REVIEW

被引:4
作者
JENSEN, NF
TODD, MM
BLOCK, RI
HEGTVEDT, RL
MCCULLOCH, TM
机构
[1] Department of Anesthesia, University of Iowa Hospitals and Clinics, Iowa City
关键词
CATHETERIZATION; CENTRAL VENOUS; MONITORING OF; SURGERY; HEAD AND NECK;
D O I
10.1016/0952-8180(94)00025-Y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To further define the efficacy of routine central venous catheter placement for major head and neck surgery from the standpoint of fluid and blood administration, and various other parameters of perioperative management. Design: Randomized, retrospective chart review. Setting: University-affiliated medical center. Patients: 104 patients who had undergone major head and neck surgery (defined as surgery lasting longer than 4 hours with a predicted blood loss of 500 ml or greater) at the University of Iowa Hospitals and Clinics between 1985 and 1992. Measurements and Main Results: Central venous monitoring was used in 51 of the 104 (49%) procedures. Patients with and without central monitors did not differ in age, weight, preoperative laboratory values [i.e., hemoglobin (Hb), blood urea nitrogen (BUN), creatinine), incidence of significant cardiac or renal disease, or a smoking history exceeding 30 pack years. In addition, these patients did not differ with respect to the following intraoperative characteristics: general type of anesthetic; duration of surgery; estimate of blood loss; Hb values; lowest urine output per hour; development of oliguria; total urine output; amount of replacement of blood, colloid or crystalloid; development of systolic blood pressure less than 70 mmHg; or use of a myocutaneous flap. Patients also did not differ with respect to the following postoperative characteristics: duration of stay in the surgical intensive care unit or hospital, BUN or creatinine values on days 1 and 2, total urine output or the development of oliguria on days 1 through 3, incidence of reintubation, fever on days 1 through 5, wound dehiscence, death, myocardial infarction, or the development of pneumonia, pulmonary edema, or sepsis. Patients with central monitors had a greater incidence of having a tracheostomy performed and a slightly lower Hb level on the first postoperative day than those without central monitors. Conclusions: The study raises doubt about the efficacy of routine central venous catheter placement as a necessary guide for fluid and blood administration for these procedures, or as a necessary adjunct for several other parameters of perioperative management. It suggests the need for a randomized, prospective evaluation
引用
收藏
页码:119 / 125
页数:7
相关论文
共 53 条
[41]  
Polos, Sahn, Complication of central venous catheter insertion: fragmentation of a guidewire with pulmonary artery embolism, Crit Care Med, 19, pp. 438-440, (1991)
[42]  
Powell, Beechey, Internal jugular catheterisation. Case report of a potentially fatal hazard, Anaesthesia, 45, pp. 458-459, (1990)
[43]  
De Silva, Earl, Sinha, Complications of a central venous line in the newborn [Letter], Arch Dis Child, 65, (1990)
[44]  
Smith, Another complication of intravenous catheterization: a case report, J Okla State Med Assoc, 83, pp. 18-20, (1990)
[45]  
Toltzis, Goldmann, Current issues in central venous catheter infection, Ann Rev Med, 41, pp. 169-176, (1990)
[46]  
Woodyard, Mellinger, Vann, Nisenbaum, Acute superior vena cava syndrome after central venous catheter placement, Cancer, 71, pp. 2621-2623, (1993)
[47]  
Yerdel, Karayalcin, Bozatli, Ertunc, An unusual outcome of a common complication of the subclavian vein catheterization [Letter], Crit Care Med, 18, pp. 796-797, (1990)
[48]  
Keats, The Rovenstine lecture, 1983: cardiovascular anesthesia: perceptions and perspectives, Anesthesiology, 60, pp. 467-474, (1984)
[49]  
Tinker, Dull, Caplan, Ward, Cheney, Role of monitoring devices in prevention of anesthetic mishaps: a closed claims analysis, Anesthesiology, 71, pp. 541-546, (1989)
[50]  
Jensen, Tinker, Quality in medical care: lessons from industry and a proposal for valid measurement and improvement, Qual Perform Qual Health Care, 1, pp. 138-153, (1993)