SIMULATION STUDY OF CEREBRAL BLOOD-FLOW MEASUREMENTS IN XENON-CT - EVALUATION OF WASHIN WASHOUT PROCEDURES

被引:7
作者
POLACIN, A
KALENDER, WA
EIDLOTH, H
机构
[1] Siemens Medical Systems, 8520, Erlangen
关键词
XENON; COMPUTED TOMOGRAPHY; BRAIN PERFUSION; SIMULATION STUDIES;
D O I
10.1118/1.596738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simulation programs have been created that allow one to vary image pixel noise, the number and the distribution of scans with time, cerebral tissue parameters, and the type of xenon CT inhalation procedure in order to investigate CBF measurements with respect to accuracy and signal-to-noise ratio (SNR). In particular, standard washin studies were compared to washin/washout studies. Based on the results of these simulations, a new protocol is suggested; it consists of only 3 min of xenon inhalation (washin phase) and 3 min of washout, monitored by one reference and six enhancement scans taken at 1-min intervals. Compared with a standard 8-min washin study of equal total dose, flow standard deviation (s.d.) for an unconstrained least-squares algorithm is reduced by factors of 2.2 and 1.2 for gray and white matter, respectively; for flow distributed uniformly from 20 to 80 ml/min/100 g, an average s.d. reduction factor of 1.7 is achieved. This was confirmed experimentally in a volunteer study using noise power spectrum analysis. In addition, effects of tissue heterogeneity have been investigated; both the bias and s.d. of flow estimates due to varying proportions of white and gray matter in a given volume element are reduced in washin/washout protocols. When compared to a short washin-only study of 4.5 min, the 3-min washin/3-min washout study provides an improvement of flow s.d. by a factor of 1.6 and 1.9 for gray and white matter, respectively. The very short xenon inhalation time and the short total examination time of the suggested new protocol are expected to significantly reduce the patient movement which is considered to be a main source of errors of xenon-CT in clinical CBF measurements.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 25 条
[1]   THE ROLE OF NOISE IN THE MEASUREMENT OF CEREBRAL BLOOD-FLOW AND PARTITION-COEFFICIENT USING XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
BEWS, J ;
DUNSCOMBE, PB ;
LEE, TY ;
MCCLARTY, B ;
KROEKER, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07) :937-945
[2]   XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW [J].
DRAYER, BP ;
WOLFSON, SK ;
REINMUTH, OM ;
DUJOVNY, M ;
BOEHNKE, M ;
COOK, EE .
STROKE, 1978, 9 (02) :123-130
[3]   THE EFFECT OF COMPUTED-TOMOGRAPHY NOISE AND TISSUE HETEROGENEITY ON CEREBRAL BLOOD-FLOW DETERMINATION BY XENON-ENHANCED COMPUTED-TOMOGRAPHY [J].
GOOD, WF ;
GUR, D .
MEDICAL PHYSICS, 1987, 14 (04) :557-561
[4]  
GOOD WF, 1991, AM J NEURORADIOL, V12, pR30
[5]   XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - MULTILEVEL CEREBRAL BLOOD-FLOW STUDIES [J].
GUR, D ;
YONAS, H ;
HERBERT, D ;
WOLFSON, SK ;
KENNEDY, WH ;
DRAYER, BP ;
GRAY, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) :334-340
[6]  
GUR D, 1989, Cerebrovascular and Brain Metabolism Reviews, V1, P68
[7]  
JACOBS A, 1990, THESIS U BONN MED SC
[8]  
KALENDER WA, 1991, 1ST P INT C STABL XE
[9]  
KALENDER WA, 1991, IN PRESS J COMP ASSI
[10]  
KASHIWAGI S, 1986, Electromedica (English Edition), V54, P136