ASSESSMENT OF POTENTIAL CONTRAST SENSITIVITY .1. PREOPERATIVE PREDICTION OF CONTRAST SENSITIVITY FOLLOWING INTRAOCULAR-LENS IMPLANTATION

被引:4
作者
MORRIS, M [1 ]
KLETT, Z [1 ]
GIESER, SC [1 ]
COUCH, JM [1 ]
HIRSCH, J [1 ]
机构
[1] YALE UNIV,DEPT OPHTHALMOL & VISUAL SCI,310 CEDAR ST,BML 225,NEW HAVEN,CT 06510
关键词
CONTRAST SENSITIVITY; INTRAOCULAR LENS; LASER INTERFEROMETRY;
D O I
10.1016/S0886-3350(13)80982-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Preoperative contrast sensitivity functions (CSFs) were determined for 15 cataract patients using laser-generated patterns that effectively bypassed the optical components of the eye. These functions were compared with postoperative CSFs determined using traditional methods by transmission through the optics of the eye. Accurate prediction of postoperative contrast sensitivity occurred in 91% of the cases (ten of 11) for patients with preoperative visual acuity of 20/200 or better and in 67% of all the cases (ten of 15). Prediction failures occurred when the laser interferometer was not able to penetrate the cataract or when postoperative complications occurred. These results suggest that preoperative measurement of laser interferometric CSF is a useful predictor of postoperative CSF for patients with mild to moderate cataracts that can be bypassed by the laser and with better than 20/200 preoperative visual acuity. The problem of assessment when lens opacity is advanced is addressed in Part II.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 23 条
[1]  
Green DG, Testing the vision of cataract patients by means of laser-generated interference fringes, Science, 168, pp. 1240-1242, (1970)
[2]  
Enoch JM, Williams RA, Essock EA, Barricks M, Hyperacuity perimetry
[3]  
assessment of macular function through ocular opacities, Arch Ophthalmol, 102, pp. 1164-1168, (1984)
[4]  
Essock EA, Williams RA, Enoch JM, Raphael S, The effects of image degradation by cataract on Vernier acuity, Invest Ophthalmol Vis Sci, 25, pp. 1043-1050, (1984)
[5]  
Enoch JM, Bedell HE, Kaufman HE, Interferometric visual acuity testing in anterior segment disease, Arch Ophthalmol, 97, pp. 1916-1919, (1979)
[6]  
Smith TW, Remijan PW, Remijan W, Et al., A new test of visual acuity using a holographic phase grating and a laser, Arch Ophthalmol, 97, pp. 752-754, (1979)
[7]  
Goldmann H, Chrenkova A, Cornaro S, Retinal visual acuity in cataractous eyes
[8]  
determination with interference fringes, Archives of Ophthalmology, 98, pp. 1778-1781, (1980)
[9]  
Faulkner W, Laser interferometric prediction of postoperative visual acuity in patients with cataracts, Am J Ophthalmol, 95, pp. 626-636, (1983)
[10]  
Minkowski JS, Palese M, Guyton DL, Potential acuity meter using a minute aerial pinhole aperture. ophthalmology, 90, pp. 1360-1368, (1983)