DETERMINATION OF AFLATOXIN Q(1) IN URINE BY AUTOMATED IMMUNOAFFINITY COLUMN CLEANUP AND LIQUID-CHROMATOGRAPHY

被引:13
作者
KUSSAK, A [1 ]
ANDERSSON, B [1 ]
ANDERSSON, K [1 ]
机构
[1] NATL INST OCCUPAT HLTH,DIV ANALYT CHEM,S-90713 UMEA,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 656卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00123-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic system with an automated clean-up procedure for aflatoxin Q(1) in human urine is described. The samples were cleaned up by using immunoaffinity columns originally designed for aflatoxin M(1). The chromatographic system was a C-18 column with an acidic mobile phase of acetonitrile-water containing potassium bromide. Fluorescence detection (365/440 nm) of aflatoxin Q(1) was enhanced by addition of bromine, using post-column derivatization, which was studied by factorial designs. Average recovery of aflatoxin Q(1) in spiked 10-ml urine samples was 88% (R.S.D. = 6.4%) at a level of 50 pg/ml. The determination limit was 49.5 pg/ml urine.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 18 条
[1]   DETERMINATION OF EXPOSURE TO AFLATOXINS AMONG DANISH WORKERS IN ANIMAL-FEED PRODUCTION THROUGH THE ANALYSIS OF AFLATOXIN-B1 ADDUCTS TO SERUM-ALBUMIN [J].
AUTRUP, JL ;
SCHMIDT, J ;
SEREMET, T ;
AUTRUP, H .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1991, 17 (06) :436-440
[2]  
BETINA V, 1989, BIOACTIVE MOL, V9
[3]  
CARLSON R, 1992, DESIGN OPTIMIZATION
[4]   TANDEM CHROMATOGRAPHIC-IMMUNOLOGICAL ANALYSES [J].
DEFRUTOS, M ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1993, 65 (01) :A17-&
[5]  
EATON DL, 1990, 1988 P S MICR TOX FO
[6]   DETERMINATION OF AFLATOXIN-M1 USING A DIALYSIS-BASED IMMUNOAFFINITY SAMPLE PRETREATMENT SYSTEM COUPLED ONLINE TO LIQUID-CHROMATOGRAPHY - REUSABLE IMMUNOAFFINITY COLUMNS [J].
FARJAM, A ;
VANDEMERBEL, NC ;
NIEMAN, AA ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :141-149
[7]  
GROOPMAN JD, 1992, CANCER EPIDEM BIOMAR, V1, P221
[8]   DETERMINATION OF AFLATOXINS IN CATTLE FEED BY LIQUID-CHROMATOGRAPHY AND POSTCOLUMN DERIVATIZATION WITH ELECTROCHEMICALLY GENERATED BROMINE [J].
KOK, WT ;
VANNEER, TCH ;
TRAAG, WA ;
TUINSTRA, LGMT .
JOURNAL OF CHROMATOGRAPHY, 1986, 367 (01) :231-236
[9]   AUTOMATED SAMPLE CLEANUP WITH SOLID-PHASE EXTRACTION FOR THE DETERMINATION OF AFLATOXINS IN URINE BY LIQUID-CHROMATOGRAPHY [J].
KUSSAK, A ;
ANDERSSON, B ;
ANDERSSON, K .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02) :235-241
[10]   METABOLISM OF AFLATOXIN-B1 IN THE BOVINE OLFACTORY MUCOSA [J].
LARSSON, P ;
PETTERSSON, H ;
TJALVE, H .
CARCINOGENESIS, 1989, 10 (06) :1113-1118