Development of a progressive dual kriging technique for 2D and 3D multi-parametric MRI data interpolation

被引:8
作者
Aissiou, Mohamed [1 ,2 ]
Perie, Delphine [1 ,2 ]
Gervais, Julien [1 ,2 ]
Trochu, Francois [1 ]
机构
[1] Ecole Polytech, Dept Mech Engn, Montreal, PQ, Canada
[2] Hosp Sainte Justine, Res Ctr, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
progressive dual kriging; magnetic resonance imaging; relaxation times; magnetisation transfer ratio; diffusion tensor imaging; interpolation; spatial resolution; filtering;
D O I
10.1080/21681163.2013.765712
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In many in vivo magnetic resonance imaging (MRI) acquisitions, the image resolution is low and induces considerable segmentation errors with a poor and limited visual interpretation. Acquiring high-resolution images reduces the patient comfort and results in considerable cost because of an increase of the acquisition time. We developed a progressive technique based on multidimensional dual kriging to interpolate 2D and 3D multi-parametric MRI data. The objectives were to (1) optimise kriging parameters for 2D images and 3D volumes interpolation, (2) validate the technique in increasing the image resolution and (3) provide a direct application to 3D non-parametric volumes interpolation and image filtering. We carried out two multi-parametric MRI acquisitions on a bovine tail segment including intervertebral discs from the second to the fourth caudal vertebrae with two different spatial resolutions. We adopted the dual kriging formulation and introduced the technique of progressive kriging, which consists in kriging the given Cartesian data region-by-region. Kriging parameters were optimised to minimise the relative errors. For each MRI sequence, kriging was compared with other interpolation techniques in terms of signal mean within the region of interest, including the zero-padding, the nearest-neighbour, the bilinear and the bicubic techniques. Optimal kriging parameters for transverse relaxation time maps interpolation were a cubic covariance function and a distance of influence of only 1-8 pixels. Our technique was found to be efficient to interpolate the longitudinal and transverse relaxation times, the magnetisation transfer ratio and the apparent diffusion coefficient maps, compared with zero-padding, nearest-neighbour, bilinear and bicubic techniques. Kriging provided relatively high performance and low error, whereas image edges tend to be corrected and better defined compared with other techniques. Progressive dual kriging is a flexible technique that can be optimised to interpolate multidimensional data based on the signal distribution and should open doors to many future applications in medical imaging such as diffusion MRI, image filtering and non-parametric 3D volume reconstruction.
引用
收藏
页码:69 / 78
页数:10
相关论文
共 35 条
[1]   Reduction of boundary artifacts in image restoration [J].
Aghdasi, F ;
Ward, RK .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (04) :611-618
[2]   Approach for the smoothing of three-dimensional reconstructions of the human spine using dual Kriging interpolation [J].
Andre, B ;
Trochu, F ;
Dansereau, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (03) :185-191
[3]   A method to reduce the Gibbs ringing artifact in MRI scans while keeping tissue boundary integrity [J].
Archibald, R ;
Gelb, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) :305-319
[4]   Morphometric evaluations of personalised 3D reconstructions and geometric models of the human spine [J].
Aubin, CE ;
Dansereau, J ;
Parent, F ;
Labella, H ;
de Guise, JA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (06) :611-618
[5]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[6]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[7]   Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy [J].
Bernstein, MA ;
Fain, SB ;
Riederer, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :270-280
[8]  
Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
[9]   Suppression of MRI Truncation Artifacts Using Total Variation Constrained Data Extrapolation [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2008, 2008
[10]   THE ORIGINS OF KRIGING [J].
CRESSIE, N .
MATHEMATICAL GEOLOGY, 1990, 22 (03) :239-252