RAPID SEPARATION OF FLUORESCEIN DERIVATIVES USING A MICROMACHINED CAPILLARY ELECTROPHORESIS SYSTEM

被引:0
作者
HARRISON, DJ [1 ]
FAN, ZH [1 ]
SEILER, K [1 ]
MANZ, A [1 ]
WIDMER, HM [1 ]
机构
[1] CIBA GEIGY AG,FORSCHUNG ANALYT,CH-4002 BASEL,SWITZERLAND
关键词
ELECTROPHORESIS; SENSORS; FLUORESCEIN; CAPILLARY ELECTROPHORESIS; MICROMACHINING;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using micromachining techniques electrophoresis systems consisting of sample injectors and separation capillaries have been fabricated in planar glass structures. A device with a total capillary channel length of 13.9 cm was used to inject and separate fluorescein and fluorescein sulfonate dyes within 3 min, with an injector to detector distance of 6.0 cin, and an applied field of 520 V/cm. A similar device with a capillary length of 1.6 cm effected injection and separation within 4 s for an injector to detector length of 0.75 cm at an applied field of 1875 V/cm. Injected sample volumes of 60 pl or less were readily injected and analyte detected at 10 muM concentrations.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 16 条
[1]  
FAN Z, UNPUB ANAL CHEM
[2]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[3]   MIXED MOBILE PHASES AND PRESSURE PROGRAMMING IN PACKED AND CAPILLARY COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY - A UNIFIED APPROACH [J].
GIORGETTI, A ;
PERICLES, N ;
WIDMER, HM ;
ANTON, K ;
DATWYLER, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (06) :318-324
[4]   INDUSTRIAL-PROCESS CONTROL BY FLOW-INJECTION ANALYSIS [J].
GISIN, M ;
THOMMEN, C .
ANALYTICA CHIMICA ACTA, 1986, 190 (01) :165-176
[5]   THE USE OF CHEMICAL SENSORS IN INDUSTRY [J].
GRABER, N ;
LUDI, H ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :239-243
[6]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[7]   ANALYSIS OF FACTORS CAUSING PEAK BROADENING IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
COLEMAN, WF ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :95-110
[8]   ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES [J].
JORGENSON, JW ;
LUKACS, KD .
ANALYTICAL CHEMISTRY, 1981, 53 (08) :1298-1302
[9]   MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS - A NOVEL CONCEPT FOR CHEMICAL SENSING [J].
MANZ, A ;
GRABER, N ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :244-248
[10]   PLANAR CHIPS TECHNOLOGY FOR MINIATURIZATION AND INTEGRATION OF SEPARATION TECHNIQUES INTO MONITORING SYSTEMS - CAPILLARY ELECTROPHORESIS ON A CHIP [J].
MANZ, A ;
HARRISON, DJ ;
VERPOORTE, EMJ ;
FETTINGER, JC ;
PAULUS, A ;
LUDI, H ;
WIDMER, HM .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :253-258