SINGLE-LEAD VDD PACING - EXCELLENCE OR EXPEDIENCE

被引:3
作者
KATRITSIS, D [1 ]
CAMM, AJ [1 ]
机构
[1] ST GEORGE HOSP,SCH MED,DEPT CARDIOL SCI,LONDON SW17 0QT,ENGLAND
关键词
PACEMAKERS; SINGLE-LEAD VDD; RATE-RESPONSIVE PACING;
D O I
10.1002/clc.4960141112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The interest in VDD pacemakers has been renewed by the introduction of single-pass leads, and continuing modifications and technical developments promise significant improvement. However, convincing long-term data confirming the reliability and the use of newer leads are not yet available. Compared with VVIR pacemakers VDD pacing has theoretical advantages over the VVIR mode, offering better hemodynamic and endocrine responses. However, its range of indications is narrow and rate adaptation is essential when sinus node chronotropic inadequacy is present or likely to occur. In addition, on certain occasions a VDD pacemaker may not maintain persistent atrial-synchronous pacing, thus necessitating the use of a DDD unit.
引用
收藏
页码:917 / 922
页数:6
相关论文
共 65 条
[1]   COMPARATIVE SURVIVAL AFTER PERMANENT VENTRICULAR AND DUAL CHAMBER PACING FOR PATIENTS WITH CHRONIC HIGH DEGREE ATRIOVENTRICULAR-BLOCK WITH AND WITHOUT PREEXISTENT CONGESTIVE-HEART-FAILURE [J].
ALPERT, MA ;
CURTIS, JJ ;
SANFELIPPO, JF ;
FLAKER, GC ;
WALLS, JT ;
MUKERJI, V ;
VILLARREAL, D ;
KATTI, SK ;
MADIGAN, NP ;
KROL, RB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) :925-932
[2]  
ANTONIOLI GE, 1989, PACE, V12, P1576
[3]  
ANTONIOLI GE, 1979, 6TH P WORLD S CARD P, P34
[4]  
ANTONIOLI GE, 1988, PROGR CLIN PACING, P39
[5]   SENSING AND PACING WITH FLOATING ELECTRODES IN THE RIGHT ATRIUM AND RIGHT ATRIAL APPENDAGE [J].
AUBERT, AE ;
GOLDREYER, BN ;
WYMAN, MG ;
ECTOR, H ;
DENYS, BG ;
DEGEEST, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) :308-315
[6]   SENSING CHARACTERISTICS OF UNIPOLAR AND BIPOLAR ORTHOGONAL FLOATING ATRIAL ELECTRODES - MORPHOLOGY AND SPECTRAL-ANALYSIS [J].
AUBERT, AE ;
ECTOR, H ;
DENYS, BG ;
DEGEEST, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (03) :343-359
[7]   COMPARISON OF THE EFFECTS OF RIGHT ATRIAL, RIGHT VENTRICULAR APEX AND ATRIOVENTRICULAR SEQUENTIAL PACING ON MYOCARDIAL OXYGEN-CONSUMPTION AND CARDIAC EFFICIENCY - A LABORATORY INVESTIGATION [J].
BALLER, D ;
WOLPERS, HG ;
ZIPFEL, J ;
BRETSCHNEIDER, HJ ;
HELLIGE, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04) :394-403
[8]   COMPARISON OF LOW RATE DUAL CHAMBER PACING TO ACTIVITY RESPONSIVE RATE VARIABLE VENTRICULAR PACING [J].
BATEY, RL ;
SWEESY, MW ;
SCALA, G ;
FORNEY, RC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (05) :646-652
[9]  
BONGIORNI MG, 1990, 9TH P INT C NEW FRON, P107
[10]  
Bubien R, 1990, PACE, V13, P524