A NEW CONTINUOUS HYDRIDE GENERATOR FOR THE DETERMINATION OF ARSENIC, ANTIMONY AND TIN BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY

被引:64
作者
LE, XC
CULLEN, WR
REIMER, KJ
BRINDLE, ID
机构
[1] ROYAL ROADS MIL COLL,DEPT CHEM,FMO,VICTORIA V0S 1B0,BC,CANADA
[2] BROCK UNIV,DEPT CHEM,ST CATHARINES L2S 3A1,ONTARIO,CANADA
关键词
ATOMIC ABSORPTION SPECTROMETRY; HYDRIDE GENERATION; ANTIMONY; ARSENIC; TIN;
D O I
10.1016/0003-2670(92)85106-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new continuous hydride generator is described. Its characteristics are compared with a conventional hydride generator for the determination of arsenic, antimony and tin by using flame atomic absorption spectrometry. This simple hydride generator combines hydride production and gas-liquid separation in one unit, obviating the use of a separate mixing/reaction coil and gas-liquid separator. Radioactive tracer studies show that a hydride generation efficiency of over 95% is achieved with the new hydride generator and that approximately 90% of monomethylarsonic acid (MMA) is converted to its hydride (methylarsine) within the first 10 s of the hydride generation reaction. Compared to a conventional hydride generator, an improved signal-to-noise ratio is achieved and comparable or less interference from transition metal ions is observed. Cysteine (1% in the sample solution) is effective in reducing interferences during the hydride generation processes. In the presence of cysteine, 10-1000 fold higher amounts of Ni2+, Co2+ and Cu2+ are tolerated in the determination of arsenic, antimony and tin. Cysteine also enhances the signals of arsenic, antimony and tin by 60, 200 and 40%, respectively. Reaction conditions were optimized by using both the simplex optimization method and one-factor-at-a-time method and results are in good agreement.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [41] Simultaneous Determination of Trace Arsenic and Antimony in Fomes Officinalis Ames with Hydride Generation Atomic Fluorescence Spectrometry
    Shuying Guo
    Bo Feng
    Huifeng Zhang
    Journal of Fluorescence, 2011, 21 : 1281 - 1284
  • [42] Simultaneous determination of arsenic and antimony by hydride generation atomic fluorescence spectrometry with dielectric barrier discharge atomizer
    Xing, Zhi
    Kuermaiti, Biekesailike
    Wang, Juan
    Han, Guojun
    Zhang, Sichun
    Zhang, Xinrong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (12) : 1056 - 1060
  • [43] Determination of arsenic, antimony, selenium, tellurium and bismuth in nickel metal by hydride generation atomic fluorescence spectrometry
    Feng, XJ
    Fu, B
    ANALYTICA CHIMICA ACTA, 1998, 371 (01) : 109 - 113
  • [44] Determination of As(III) and total inorganic arsenic by flow injection hydride generation atomic absorption spectrometry
    Coelho, NMM
    da Silva, AC
    da Silva, CM
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 227 - 233
  • [45] An automated continuous homogeneous microextraction for the determination of selenium and arsenic by hydride generation atomic fluorescence spectrometry
    Shishov, Andrey
    Wieczorek, Marcin
    Koscielniak, Pawel
    Dudek-Adamska, Danuta
    Telk, Anna
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2018, 181 : 359 - 365
  • [46] CROSS-INTERFERENCES OF HYDRIDE-FORMING ELEMENTS IN HYDRIDE-GENERATION ATOMIC-ABSORPTION SPECTROMETRY
    BARTH, P
    KRIVAN, V
    HAUSBECK, R
    ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) : 111 - 118
  • [47] Hydride generation-electrostatic deposition-graphite furnace atomic absorption spectrometric determination of arsenic, selenium and antimony
    Camero, RM
    Sturgeon, RE
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) : 753 - 762
  • [48] Analytical conditions for the determination of arsenic, antimony and selenium by atomic absorption spectrometry with generation of hydrides
    Niedzielski, P
    Siepak, M
    Siepak, J
    CHEMIA ANALITYCZNA, 2002, 47 (06): : 807 - 822
  • [49] Sequential injection analysis system for the determination of arsenic by hydride generation atomic absorption spectrometry
    Yin, XF
    Zhang, JJ
    Wang, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1365 - 1367
  • [50] IMPROVEMENT IN ARSENIC SPECIATION, USING HYDRIDE GENERATION AND ATOMIC-ABSORPTION SPECTROPHOTOMETRY
    MICHEL, P
    AVERTY, B
    COLANDINI, V
    MIKROCHIMICA ACTA, 1992, 109 (1-4) : 35 - 38