A NEW CONTINUOUS HYDRIDE GENERATOR FOR THE DETERMINATION OF ARSENIC, ANTIMONY AND TIN BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY

被引:64
作者
LE, XC
CULLEN, WR
REIMER, KJ
BRINDLE, ID
机构
[1] ROYAL ROADS MIL COLL,DEPT CHEM,FMO,VICTORIA V0S 1B0,BC,CANADA
[2] BROCK UNIV,DEPT CHEM,ST CATHARINES L2S 3A1,ONTARIO,CANADA
关键词
ATOMIC ABSORPTION SPECTROMETRY; HYDRIDE GENERATION; ANTIMONY; ARSENIC; TIN;
D O I
10.1016/0003-2670(92)85106-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new continuous hydride generator is described. Its characteristics are compared with a conventional hydride generator for the determination of arsenic, antimony and tin by using flame atomic absorption spectrometry. This simple hydride generator combines hydride production and gas-liquid separation in one unit, obviating the use of a separate mixing/reaction coil and gas-liquid separator. Radioactive tracer studies show that a hydride generation efficiency of over 95% is achieved with the new hydride generator and that approximately 90% of monomethylarsonic acid (MMA) is converted to its hydride (methylarsine) within the first 10 s of the hydride generation reaction. Compared to a conventional hydride generator, an improved signal-to-noise ratio is achieved and comparable or less interference from transition metal ions is observed. Cysteine (1% in the sample solution) is effective in reducing interferences during the hydride generation processes. In the presence of cysteine, 10-1000 fold higher amounts of Ni2+, Co2+ and Cu2+ are tolerated in the determination of arsenic, antimony and tin. Cysteine also enhances the signals of arsenic, antimony and tin by 60, 200 and 40%, respectively. Reaction conditions were optimized by using both the simplex optimization method and one-factor-at-a-time method and results are in good agreement.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [31] DETERMINATION OF ARSENIC IN HELIANTHUS ANNUUS L. BY HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY
    Gulay, S.
    Ayca, K.
    Yildiz, K.
    GLOBAL NEST JOURNAL, 2015, 17 (01): : 140 - 147
  • [32] Ultratrace determination of tin by hydride generation in-atomizer trapping atomic absorption spectrometry
    Prusa, Libor
    Dedina, Jiri
    Kratzer, Jan
    ANALYTICA CHIMICA ACTA, 2013, 804 : 50 - 58
  • [33] Determination of trace arsenic and mercury in antimony concentrates by hydride generation atomic fluorescence spectrometry
    Yuan Ai-ping
    Tang Yan-xia
    Huang Yu-long
    Wang Jing-ling
    Qin Ran
    Wu Jian-ling
    Meng Wen-fei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (08) : 1553 - 1556
  • [34] Determination of arsenic and antimony by microwave plasma atomic emission spectrometry coupled with hydride generation and a PTFE membrane separator
    Gong, ZB
    Chan, WF
    Wang, XR
    Lee, FSC
    ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) : 207 - 214
  • [35] DETERMINATION OF GERMANIUM, ARSENIC, SELENIUM, TIN AND ANTIMONY IN COMPLEX SAMPLES BY HYDRIDE GENERATION - MICROWAVE-INDUCED PLASMA ATOMIC-EMISSION SPECTROMETRY
    ROBBINS, WB
    CARUSO, JA
    FRICKE, FL
    ANALYST, 1979, 104 (1234) : 35 - 40
  • [36] Determination of antimony by using a quartz atom trap and electrochemical hydride generation atomic absorption spectrometry
    Menemenlioglu, Ipek
    Korkmaz, Deniz
    Ataman, O. Yavuz
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (01) : 40 - 47
  • [37] Determination of arsenic in biological material by hydride generation atomic absorption spectrometry method
    Szkoda, Jozef
    Zmudzki, Jan
    Grzebalska, Agnieszka
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2006, 50 (02) : 269 - 272
  • [38] Determination of inorganic and total arsenic in wines by hydride generation atomic absorption spectrometry
    Tasev, K
    Karadjova, I
    Stafilov, T
    MICROCHIMICA ACTA, 2005, 149 (1-2) : 55 - 60
  • [39] DETERMINATION OF TRACE TIN BY CONTINUOUS FLOW HYDRIDE GENERATION LASER INDUCED FLUORESCENCE SPECTROMETRY
    Ezer, Muhsin
    Simeonsson, Josef B.
    FRESENIUS ENVIRONMENTAL BULLETIN, 2009, 18 (09): : 1572 - 1577
  • [40] Simultaneous Determination of Trace Arsenic and Antimony in Fomes Officinalis Ames with Hydride Generation Atomic Fluorescence Spectrometry
    Guo, Shuying
    Feng, Bo
    Zhang, Huifeng
    JOURNAL OF FLUORESCENCE, 2011, 21 (03) : 1281 - 1284