A TRIGGER FOR THE FERMILAB-E760 LEAD-GLASS CALORIMETER

被引:12
作者
RAY, R [1 ]
ROSEN, JL [1 ]
MASUZAWA, M [1 ]
ZHAO, J [1 ]
机构
[1] NORTHWESTERN UNIV,EVANSTON,IL 60208
关键词
D O I
10.1016/0168-9002(91)90190-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The E760 #1 experiment at Fermi National Laboratory has been commissioned to study electromagnetic decay channels of charmonium states. A trigger has been built for the 1280-element lead-glass calorimeter to facilitate the study of all-neutral decay modes. The trigger has also proven to be extremely useful for charged electromagnetic final states. The trigger has been successfully deployed and has shown itself to be reliable and highly efficient. The design and performance of this trigger are described in detail.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 9 条
[1]   THE E760 LEAD-GLASS CENTRAL CALORIMETER - DESIGN AND INITIAL TEST-RESULTS [J].
BARTOSZEK, L ;
BHARADWAJ, V ;
CHURCH, MD ;
HAHN, AA ;
PEOPLES, J ;
PORDES, SH ;
RAPIDIS, PA ;
WERKEMA, SJ ;
AGAHI, D ;
BROEMMELSIEK, DR ;
FAST, JE ;
GEE, M ;
GOLLWITZER, KE ;
MANDELKERN, MA ;
MARQUES, JL ;
SCHULTZ, J ;
WEBER, MF ;
GINSBURG, CM ;
MASUZAWA, M ;
RAY, RE ;
ROSEN, JL ;
TROKENHEIM, S ;
ZHAO, JL ;
ARMSTRONG, TA ;
HUFFORD, GE ;
LEWIS, RA ;
MAJEWSKA, AM ;
REID, JD ;
SMITH, GA ;
HASAN, MA ;
BIINO, C ;
PALESTINI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (01) :47-60
[2]   CHARGE DIVISION IN A SMALL PROPORTIONAL CHAMBER CONSTRUCTED WITH ALUMINIZED MYLAR TUBES [J].
BIINO, C ;
MUSSA, R ;
PALESTINI, S ;
PASTRONE, N ;
PESANDO, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03) :417-422
[3]  
BIINO C, 1989, IEEE T NUCL SCI, V336, P98
[4]   ELASTIC SCATTERING PION PRODUCTION AND ANNIHILATION INTO PIONS IN ANTIPROTON-PROTON INTERACTIONS AT 5.7 GEV/C [J].
BOCKMANN, K ;
NELLEN, B ;
PAUL, E ;
WAGINI, B ;
BORECKA, I ;
DIAZ, J ;
HEEREN, U ;
LIEBERMEISTER, U ;
LOHRMANN, E ;
RAUBOLD, E ;
SODING, P ;
WOLFF, S ;
KIDD, J ;
MANDELLI, L ;
MOSCA, L ;
PELOSI, V ;
RATTI, S ;
TALLONE, L .
NUOVO CIMENTO A, 1966, 44 (01) :316-+
[5]  
BOOTH CN, 1983, PHYS REV D, V27, P2015
[6]   A CYLINDRICAL MWPC AND RADIAL PROJECTION CHAMBER FOR THE E760 EXPERIMENT [J].
CALABRESE, R ;
CARASSITI, V ;
DALPIAZ, P ;
DALPIAZ, PF ;
LUPPI, E ;
MARTINI, M ;
PALESTINI, S ;
PETRUCCI, F ;
SAVRIE, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (01) :116-120
[7]   VERY LIGHT TRACKING DETECTOR FOR JET TARGET EXPERIMENT IN HIGH-ENERGY PHYSICS [J].
CALABRESE, R ;
CARASSITI, V ;
DALPIAZ, P ;
DALPIAZ, PF ;
LUPPI, E ;
MARTINI, M ;
PETRUCCI, F ;
SAVRIE, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :54-57
[8]   THE FERMILAB-E760 FORWARD ELECTROMAGNETIC CALORIMETER [J].
HASAN, MA ;
GILBERT, SG ;
KEILHOLTZ, K ;
ARMSTRONG, TA ;
LEWIS, RA ;
MAJEWSKA, A ;
MINOR, ED ;
PASSANEAU, J ;
REID, JD ;
SMITH, GA ;
MARIOTTI, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2) :73-80
[9]  
REGAN T, 1990, FN544 FERM LAB