DETERMINATION OF CEFTAZIDIME IN DOLPHIN SERUM BY LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET VISIBLE DETECTION AND CONFIRMATION BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:18
|
作者
TYCZKOWSKA, KL [1 ]
SEAY, SS [1 ]
STOSKOPF, MK [1 ]
STOSKOPF, MK [1 ]
AUCOIN, DP [1 ]
机构
[1] N CAROLINA STATE UNIV,COLL VET MED,DEPT COMPANION ANIM & SPECIAL SPECIES MED,RALEIGH,NC 27606
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 576卷 / 02期
关键词
D O I
10.1016/0378-4347(92)80204-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive liquid chromatographic method has been developed for the determination of therapeutic levels of ceftazidime in dolphin serum. The method involved an ultrafiltration of diluted serum with an equal amount of acetonitrile-ethanol-water (40:40:20, v/v/v) through a 10 000 daltons molecular mass cut-off filter. Separation of ceftazidime from the other serum components was performed by ion-paired (dodecanesulfonate) liquid chromatography using a reversed-phase column eluted with acetonitrile-water solution. The ultraviolet absorbance of the column effluent was monitored in the 200-340 nm range of a photodiode-array detector or at 258.8 nm on a variable-wavelength ultraviolet-visible detector. Recoveries of ceftazidime from dolphin serum spiked with 20 and 2-mu-g/ml were 92.9 and 91.1% with coefficients of variation of 5.5 and 5.7%, respectively. A correlation coefficient of 0.9994 occurred with ceftazidime in aqueous solutions (n = 6, in duplicates). The limit of detection for this antibiotic was estimated to be approximately 50 ppb (ng/ml). The unbound ceftazidime concentrations in dosed dolphin serum were determined to calculate the protein bindings of this antibiotic which yielded 32 +/- 2%. The ceftazidime peak identity in dosed dolphin serum was confirmed by thermospray liquid chromatography-mass spectrometry. The thermospray mass spectrum of ceftazidime exhibited only the fragment ions, involving the opening of the beta-lactam ring, at m/z 237,255 and 315 when positive-ion detection mode was employed and the fragment ions at m/z 235, 253 and 313 when negative-ion detection mode was used.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 50 条
  • [21] SIMULTANEOUS DETERMINATION OF SULFONAMIDES IN MEAT BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    HORIE, M
    SAITO, K
    HOSHINO, Y
    NOSE, N
    TERA, M
    KITSUWA, T
    NAKAZAWA, H
    YAMANE, Y
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1990, 36 (04): : 283 - 289
  • [22] SENSITIVE METHOD FOR THE DETERMINATION OF PENTAMORPHONE IN SERUM BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH THERMOSPRAY INTERFACE
    KESWANI, SR
    EDFORT, MJ
    WILHELM, JA
    KVALO, LT
    VENTURELLA, VS
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 : 77 - 86
  • [23] DIRECT LIQUID INTRODUCTION THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    COVEY, T
    HENION, J
    ANALYTICAL CHEMISTRY, 1983, 55 (14) : 2275 - 2280
  • [24] ANALYSIS OF XENOBIOTIC CONJUGATES BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    DULIK, DM
    KUO, GY
    DAVIS, MR
    RHODES, GR
    ACS SYMPOSIUM SERIES, 1990, 420 : 124 - 139
  • [25] URINARY METABOLIC PROFILING BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BUCHANAN, DN
    MUENZER, J
    THOENE, JG
    PEDIATRIC RESEARCH, 1990, 27 (04) : A129 - A129
  • [26] ONLINE LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY IN THE ANALYSIS OF OLIGOSACCHARIDES
    NIESSEN, WMA
    VANDERHOEVEN, RAM
    VANDERGREEF, J
    SCHOLS, HA
    VORAGEN, AGJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (03) : 197 - 202
  • [27] EVALUATION OF THE POTENTIAL OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN NEUROCHEMISTRY
    ARTIGAS, F
    GELPI, E
    JOURNAL OF CHROMATOGRAPHY, 1987, 394 (01): : 123 - 134
  • [28] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN DEUTERIUM-OXIDE
    EDMONDS, CG
    POMERANTZ, SC
    HSU, FF
    MCCLOSKEY, JA
    ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2314 - 2317
  • [29] TECHNIQUES FOR INCREASED USE OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    MCFADDEN, WH
    LAMMERT, SA
    JOURNAL OF CHROMATOGRAPHY, 1987, 385 : 201 - 211
  • [30] DETERMINATION OF ORGANO-PHOSPHORUS ACIDS BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    WILS, ERJ
    HULST, AG
    JOURNAL OF CHROMATOGRAPHY, 1988, 454 : 261 - 272