Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations

被引:12
作者
Livingstone, Roshan S. [1 ]
Dinakaran, Paul M. [1 ]
Cherian, Rekha S. [1 ]
Eapen, Anu [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Radiol, Vellore 632004, Tamil Nadu, India
关键词
Abdominal computed tomography; dose modulation; effective dose; image quality;
D O I
10.4103/0971-6203.56085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) of the abdomen contributes a substantial amount of man-made radiation dose to patients and use of this modality is on the increase. This study intends to compare radiation dose and image quality using dose modulation techniques and weight- based protocol exposure parameters for biphasic abdominal CT. Using a six-slice CT scanner, a prospective study of 426 patients who underwent abdominal CT examinations was performed. Constant tube potentials of 90 kV and 120 kV were used for all arterial and portal venous phase respectively. The tube current-time product for weight-based protocol was optimized according to patients body weight; this was automatically selected in dose modulations. The effective dose using weight-based protocol, angular and z-axis dose modulation was 11.3 mSv, 9.5 mSv and 8.2 mSv respectively for the patients body weight ranging from 40 to 60 kg. For patients of body weights ranging 60 to 80 kg, the effective doses were 13.2 mSv, 11.2 mSv and 10.6 mSv respectively. The use of dose modulation technique resulted in a reduction of 16 to 28% in radiation dose with acceptable diagnostic accuracy in comparison to the use of weight-based protocol settings.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 30 条
[1]  
ACR, 1891, VA20191 ACR
[2]   Wavelet Based Noise Reduction in CT-Images Using Correlation Analysis [J].
Borsdorf, Anja ;
Raupach, Rainer ;
Flohr, Thomas ;
Hornegger, Joachim .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) :1685-1703
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[5]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[6]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[7]   Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey [J].
Brix, G ;
Nagel, HD ;
Stamm, G ;
Veit, R ;
Lechel, U ;
Griebel, J ;
Galanski, M .
EUROPEAN RADIOLOGY, 2003, 13 (08) :1979-1991
[8]  
European Commission, 1999, 16262 EUR EN
[9]   Radiation doses from CT in the Sultanate of Oman [J].
Goddard, CC ;
Al-Farsi, A .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (863) :1073-1077
[10]  
Hart D, 2002, 14 NRPBW