Pre-Procedural Imaging Modalities for Device Size Selection and Adaptive Nature of the Appendage in Patients Undergoing Percutaneous Left Atrial Appendage Closure

被引:3
作者
Chow, Danny H. F. [1 ]
Bieliauskas, Gintautas [1 ]
Sawaya, Fadi J. [1 ]
Millan-Iturbe, Oscar [1 ]
Kofoed, Klaus F. [1 ]
De Backer, Ole [1 ]
Sondergaard, Lars [1 ]
机构
[1] Rigshosp, Univ Hosp, Heart Ctr, Copenhagen, Denmark
来源
STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM | 2018年 / 2卷 / 01期
关键词
Angiography; atrial fibrillation; left atrial appendage; multi-slice computed tomography; transesophageal echocardiography;
D O I
10.1080/24748706.2017.1405174
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to compare different pre-procedural left atrial appendage (LAA) imaging modalities and analyze the anatomical adaptation of the LAA to the closure device at 3-month multi-slice computed tomography (MSCT). LAA closure device sizing is crucial to optimize immediate and long-term outcomes. Methods: Patients who underwent percutaneous LAA closure and had pre-procedural transesophageal echocardiography (TEE) and MSCT were identified. Devices used were Amulet(TM) (Abbott, USA), Watchman(TM,) and WatchmanFLX(TM) (Boston Scientific, USA). LAA ostium and landing zone were measured according to the instructions for use at 2D-TEE, as well as at MSCT and X-ray angiography. Post-procedural MSCT was used to assess LAA ellipticity and closure. Results: A total of 67 patients (44 Amulet(TM), 11 Watchman(TM), 12 WatchmanFLX(TM)) were included. Mean age was 74 +/- 7 years, CHA(2)DS(2)-VASc-score 3.0 +/- 1.6 and HAS-BLED-score 2.7 +/- 0.9. Bland-Altman analysis for the maximum LAA diameter at MSCT (CTmax) and TEE (TEEmax) showed a mean difference of +4.8 mm with a limit of agreement (LoA) of 9.6 mm (p < 0.01). Maximum LAA diameters at TEE (TEEmax) and X-ray angiography (XA(max)) showed a mean difference of +1.3 mm with LoA of 7.6 mm (p = 0.839). The mean difference between CTmean and TEEmax was +2.1 mm with LoA of 8.4 mm (p < 0.05). In addition, LAA ellipticity ratio decreased from 1.48 to 1.05 while overall LAA area only expanded 3% after device implantation. Conclusion: Of the three imaging modalities, MSCT provides the largest LAA measurements, followed by TEE and angiography. At follow-up MSCT, the elliptical LAA conforms to the circular shape of the closure device; however, overall LAA expansion is only minimal.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 14 条
[1]   Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation [J].
Blackshear, JL ;
Odell, JA .
ANNALS OF THORACIC SURGERY, 1996, 61 (02) :755-759
[2]   Left atrial function: physiology, assessment, and clinical implications [J].
Blume, Gustavo G. ;
Mcleod, Christopher J. ;
Barnes, Marion E. ;
Seward, James B. ;
Pellikka, Patricia A. ;
Bastiansen, Paul M. ;
Tsang, Teresa S. M. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (06) :421-430
[3]   Analysis of in vivo left atrial appendage morphology in patients with atrial fibrillation: a direct comparison of transesophageal echocardiography, planar cardiac CT, and segmented three-dimensional cardiac CT [J].
Budge, Loren P. ;
Shaffer, Katherine M. ;
Moorman, J. Randall ;
Lake, Douglas E. ;
Ferguson, John D. ;
Mangrum, J. Michael .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (02) :87-93
[4]  
Chow DHF, 2017, OPEN HEART, V4, DOI 10.1136/openhrt-2017-000627
[5]   Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update [J].
De Backer, O. ;
Arnous, S. ;
Ihlemann, N. ;
Vejlstrup, N. ;
Jorgensen, E. ;
Pehrson, S. ;
Krieger, T. D. W. ;
Meier, P. ;
Sondergaard, L. ;
Franzen, O. W. .
OPEN HEART, 2014, 1 (01)
[6]   Three-Dimensional Multidetector Computed Tomography versus Conventional 2-Dimensional Transesophageal Echocardiography for Annular Sizing in Transcatheter Aortic Valve Replacement: Influence on Postprocedural Paravalvular Aortic Regurgitation [J].
Hansson, Nicolaj C. ;
Thuesen, Leif ;
Hjortdal, Vibeke E. ;
Leipsic, Jonathon ;
Andersen, Henning R. ;
Poulsen, Steen H. ;
Webb, John G. ;
Christiansen, Evald H. ;
Rasmussen, Lars E. ;
Krusell, Lars R. ;
Terp, Kim ;
Klaaborg, Kaj E. ;
Tang, Mariann ;
Lassen, Jens F. ;
Botker, Hans E. ;
Norgaard, Bjarne L. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (06) :977-986
[7]   Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial [J].
Holmes, David R. ;
Reddy, Vivek Y. ;
Turi, Zoltan G. ;
Doshi, Shephal K. ;
Sievert, Horst ;
Buchbinder, Maurice ;
Mullin, Christopher M. ;
Sick, Peter .
LANCET, 2009, 374 (9689) :534-542
[8]   2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS [J].
Kirchhof, Paulus ;
Benussi, Stefano ;
Kotecha, Dipak ;
Ahlsson, Anders ;
Atar, Dan ;
Casadei, Barbara ;
Castella, Manuel ;
Diener, Hans-Christoph ;
Heidbuchel, Hein ;
Hendriks, Jeroen ;
Hindricks, Gerhard ;
Manolis, Antonis S. ;
Oldgren, Jonas ;
Popescu, Bogdan Alexandru ;
Schotten, Ulrich ;
Van Putte, Bart ;
Vardas, Panagiotis .
EUROPEAN HEART JOURNAL, 2016, 37 (38) :2893-+
[9]   Erroneous Measurement of the Aortic Annular Diameter Using 2-Dimensional Echocardiography Resulting in Inappropriate CoreValve Size Selection A Retrospective Comparison With Multislice Computed Tomography [J].
Mylotte, Darren ;
Dorfmeister, Magdalena ;
Elhmidi, Yacine ;
Mazzitelli, Domenico ;
Bleiziffer, Sabine ;
Wagner, Anke ;
Noterdaeme, Timothee ;
Lange, Ruediger ;
Piazza, Nicolo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) :652-661
[10]   Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography Implications for Catheter-Based Left Atrial Appendage Closure [J].
Nucifora, Gaetano ;
Faletra, Francesco F. ;
Regoli, Francois ;
Pasotti, Elena ;
Pedrazzini, Giovanni ;
Moccetti, Tiziano ;
Auricchio, Angelo .
CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (05) :514-523