Validation of the integration of technology that measures additional "vascular" indices into an ambulatory blood pressure monitoring system

被引:20
作者
Kotovskaya, Yulia V. [1 ]
Kobalava, Zhanna D. [1 ]
Orlov, Artemy V. [2 ]
机构
[1] Peoples Friendship Univ Russia, Propedeut Dept, Moscow, Russia
[2] Natl Res Nucl Univ MEPhI, Competit Syst Anal Dept, Kashirskoye shosse 31, Moscow 115409, Russia
关键词
validation study; ambulatory; 24-hour; monitoring; arterial stiffness; pulse wave velocity; augmentation index; central blood pressure;
D O I
10.2147/MDER.S61839
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objective of this study was to validate the novel integration of oscillometric (Vasotens((R))) technology into a BPLab((R)) ambulatory blood pressure (BP) monitoring system to measure central BP, the aortic augmentation index, and pulse wave velocity (PWV) compared with the recommended and widely accepted tonometric method. Methods: The ARTERY Society guidelines for comparison of PWV measurement techniques were used as the basis for recruitment of 99 individuals (mean age 44 +/- 19 years, 52 males). The standard for comparison was the conventional "classic" SphygmoCor device. Results: Accordance of the two methods was satisfactory (r=0.98, mean difference of 2.9 +/- 3.5 mmHg for central systolic BP; r=0.98, mean difference of-1.1 +/- 2.3 mmHg for central diastolic BP; r=0.83, mean difference of-2.6%+/- 13% for aortic augmentation index; r=0.85, mean difference of 0.69 +/- 1.4 for PWV). Conclusion: The performance of Vasotens algorithms using an oscillometric ambulatory BP monitoring system is feasible for accurate diagnosis, risk assessment, and evaluation of the effects of antihypertensive drugs.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 33 条
[1]  
Ageenkova OA, 2011, VASC HEALTH RISK MAN, V7, P649, DOI 10.2147/VHRM.S24877
[2]   A new oscillometric method for assessment of arterial stiffness:: comparison with tonometric and piezo-electronic methods [J].
Baulmann, Johannes ;
Schillings, Ulrich ;
Rickert, Susanna ;
Uen, Sakir ;
Duesing, Rainer ;
Illyes, Miklos ;
Cziraki, Attila ;
Nickering, Georg ;
Mengden, Thomas .
JOURNAL OF HYPERTENSION, 2008, 26 (03) :523-528
[3]   Aortic Pulse Wave Velocity Improves Cardiovascular Event Prediction An Individual Participant Meta-Analysis of Prospective Observational Data From 17,635 Subjects [J].
Ben-Shlomo, Yoav ;
Spears, Melissa ;
Boustred, Chris ;
May, Margaret ;
Anderson, Simon G. ;
Benjamin, Emelia J. ;
Boutouyrie, Pierre ;
Cameron, James ;
Chen, Chen-Huan ;
Cruickshank, J. Kennedy ;
Hwang, Shih-Jen ;
Lakatta, Edward G. ;
Laurent, Stephane ;
Maldonado, Joao ;
Mitchell, Gary F. ;
Najjar, Samer S. ;
Newman, Anne B. ;
Ohishi, Mitsuru ;
Pannier, Bruno ;
Pereira, Telmo ;
Vasan, Ramachandran S. ;
Shokawa, Tomoki ;
Sutton-Tyrell, Kim ;
Verbeke, Francis ;
Wang, Kang-Ling ;
Webb, David J. ;
Hansen, Tine Willum ;
Zoungas, Sophia ;
McEniery, Carmel M. ;
Cockcroft, John R. ;
Wilkinson, Ian B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (07) :636-646
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Aortic stiffness is an independent predictor of primary coronary events in hypertensive patients - A longitudinal study [J].
Boutouyrie, P ;
Tropeano, AI ;
Asmar, R ;
Gautier, I ;
Benetos, A ;
Lacolley, P ;
Laurent, S .
HYPERTENSION, 2002, 39 (01) :10-15
[6]   Estimation of central systolic blood pressure using an oscillometric blood pressure monitor [J].
Cheng, Hao-Min ;
Wang, Kang-Ling ;
Chen, Ying-Hwa ;
Lin, Shing-Jong ;
Chen, Lung-Ching ;
Sung, Shih-Hsien ;
Ding, Philip Yu-An ;
Yu, Wen-Chung ;
Chen, Jaw-Wen ;
Chen, Chen-Huan .
HYPERTENSION RESEARCH, 2010, 33 (06) :592-599
[7]   Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements [J].
Hametner, Bernhard ;
Wassertheurer, Siegfried ;
Kropf, Johannes ;
Mayer, Christopher ;
Eber, Bernd ;
Weber, Thomas .
BLOOD PRESSURE MONITORING, 2013, 18 (03) :173-176
[8]   2013 Ambulatory Blood Pressure Monitoring Recommendations for the Diagnosis of Adult Hypertension, Assessment of Cardiovascular and other Hypertension-associated Risk, and Attainment of Therapeutic Goals [J].
Hermida, Ramon C. ;
Smolensky, Michael H. ;
Ayala, Diana E. ;
Portaluppi, Francesco ;
Crespo, Juan J. ;
Fabbian, Fabio ;
Haus, Erhard ;
Manfredini, Roberto ;
Mojon, Artemio ;
Moya, Ana ;
Pineiro, Luis ;
Rios, Mara T. ;
Otero, Alfonso ;
Balan, Horia ;
Fernandez, Jose R. .
CHRONOBIOLOGY INTERNATIONAL, 2013, 30 (03) :355-410
[9]   Validation of the BPLab((R)) 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocol [J].
Koudryavtcev, Sergey A. ;
Lazarev, Vyacheslav M. .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2011, 4 :193-196
[10]   Expert consensus document on arterial stiffness: methodological issues and clinical applications [J].
Laurent, Stephane ;
Cockcroft, John ;
Van Bortel, Luc ;
Boutouyrie, Pierre ;
Giannattasio, Cristina ;
Hayoz, Daniel ;
Pannier, Bruno ;
Vlachopoulos, Charalambos ;
Wilkinson, Ian ;
Struijker-Boudier, Harry .
EUROPEAN HEART JOURNAL, 2006, 27 (21) :2588-2605