A TRIBOLOGICAL STUDY OF A SERIES OF RETRIEVED ACCORD KNEE EXPLANTS

被引:16
作者
HAILEY, JL
FISHER, J
DOWSON, D
SAMPATH, SA
JOHNSON, R
ELLOY, M
机构
[1] UNIV LIVERPOOL,DEPT ORTHOPAED & ACCID SURG,LIVERPOOL,MERSEYSIDE,ENGLAND
[2] DEPUY INT LTD,LEEDS LS11 8DT,W YORKSHIRE,ENGLAND
[3] ARROWEPK HOSP,KNEE RES UNIT,WIRRAL L49 5PE,MERSEYSIDE,ENGLAND
基金
澳大利亚研究理事会;
关键词
TRIBOLOGY; RETRIEVAL; KNEE PROSTHESES;
D O I
10.1016/1350-4533(94)90041-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A tribological study of a series of 27 retrieved Accord meniscal bearing knee joints has been carried out. The roughness of the articulating surfaces of the meniscal and the femoral components was investigated, and the penetration into the polyethylene meniscal component was determined. There was generally little damage to the highly polished metallic femoral components. A general polishing and smoothing of the ultra high molecular weight polyethylene meniscal components mar observed although there was some subsequent deterioration of the polyethylene surfaces in certain cases. The penetration rate of the femoral components into the menisci was low, and was found to be similar to that reported for other meniscal knee joints.
引用
收藏
页码:223 / 228
页数:6
相关论文
共 16 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[3]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[4]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, V273, P232
[5]   MACROSCOPIC AND MICROSCOPIC WEAR MECHANISMS IN ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE [J].
COOPER, JR ;
DOWSON, D ;
FISHER, J .
WEAR, 1993, 162 :378-384
[6]  
Dowling JM, 1983, BIOCOMPATIBLE POLYM, P407
[7]  
Dowson D, 1988, Eng Med, V17, P111, DOI 10.1243/EMED_JOUR_1988_017_031_02
[8]  
DOWSON D, 1991, UHMWPE BIOMATERIAL O, P32
[9]   POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES [J].
ENGH, GA ;
DWYER, KA ;
HANES, CK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01) :9-17
[10]  
GOODFELLOW J, 1992, J BONE JOINT SURG BR, V74, P1