ARTERIOVENOUS DIFFERENCES IN PCO2 AND CARDIAC-OUTPUT DURING CPR IN THE DOG

被引:13
作者
SATO, S
OKUBO, N
SATSUMAE, T
KUMAGAI, M
YAMAMOTO, S
NAKAYAMA, H
TAGUCHI, N
机构
[1] Department of Anesthesiology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki
关键词
CPR; ARTERIOVENOUS DIFFERENCES (AVD) OF CO2; END-TIDAL CO2; CARDIAC OUTPUT;
D O I
10.1016/0300-9572(94)90039-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Using 14 mongrel dogs, we investigated the correlation between arteriovenous differences of PCO2 (AVD-CO2) and cardiac output (CO) during CPR. Ventricular fibrillation was induced by an electrical current and the respirator was stopped for 5 min. Cardiopulmonary resuscitation (CPR) was performed during the next 10 min and CO was measured with simultaneous arterial and venous blood gas analysis. CO was measured 26 times during CPR. The animals were divided into two groups according to the values of CO during CPR: low-CO group (CO < 0.3 1/min) and high-CO group (CO greater-than-or-equal-to 0.3 l/min). AVD-CO2 in the low CO group was 39.8 +/- 5.7 mmHg and that of the high group was 27.4 +/- 14.8 mmHg (mean +/- S.D., P < 0.05). In conclusion, AVD-CO2 showed an inverse result with the degree of CO during CPR.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [31] ASSESSMENT OF CARDIAC-OUTPUT DURING EXERCISE - TRANSTHORACIC IMPEDANCE VS HEART-RATE ALONE
    HORSTMANN, E
    KONN, B
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1993, 19 (04) : 173 - 178
  • [32] MIC-II - PROGRAM FOR DETERMINATION OF CARDIAC-OUTPUT, ARTERIOVENOUS SHUNT AND REGIONAL BLOOD-FLOW USING RADIOACTIVE MICROSPHERE METHOD
    SCHOSSER, R
    ARFORS, KE
    MESSMER, K
    COMPUTER PROGRAMS IN BIOMEDICINE, 1979, 9 (01): : 19 - 38
  • [33] POSTURAL EFFECT ON CARDIAC-OUTPUT, OXYGEN-UPTAKE AND LACTATE DURING CYCLE EXERCISE OF VARYING INTENSITY
    LEYK, D
    ESSFELD, D
    HOFFMANN, U
    WUNDERLICH, HG
    BAUM, K
    STEGEMANN, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 68 (01): : 30 - 35
  • [34] COMPARISON OF ESTIMATES OF CARDIAC-OUTPUT BY INDICATOR DILUTION AND FREON 22 UPTAKE DURING GAS MIXING IN DOGS
    JONES, HA
    LAKSHMINARAYAN, S
    BECKET, JM
    HUGHES, JMB
    CARDIOVASCULAR RESEARCH, 1991, 25 (06) : 523 - 528
  • [35] RELIABILITY OF 1ST-PASS RADIONUCLIDE DETERMINATION OF CARDIAC-OUTPUT IN THE UPRIGHT POSITION AT REST AND DURING EXERCISE
    KELBAEK, H
    GJORUP, T
    HVIDJACOBSEN, K
    SKAGEN, K
    MUNCK, O
    GODTFREDSEN, J
    HESLET, L
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (11): : 955 - 959
  • [36] EFFECT OF RATE-ADAPTING ATRIOVENTRICULAR DELAY ON STROKE VOLUME AND CARDIAC-OUTPUT DURING ATRIAL SYNCHRONOUS PACING
    REES, M
    HAENNEL, RG
    BLACK, WR
    KAPPAGODA, T
    CANADIAN JOURNAL OF CARDIOLOGY, 1990, 6 (10) : 445 - 452
  • [37] CARDIAC-OUTPUT VARIATIONS IN SUPINE RESTING SUBJECTS DURING HEAD-OUT COLD-WATER IMMERSION
    VOGELAERE, P
    DEKLUNDER, G
    LECROART, J
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1995, 39 (01) : 40 - 45
  • [38] EFFECT OF SODIUM-NITROPRUSSIDE ON CARDIAC-OUTPUT DURING CROSS-CLAMPING OF THE DESCENDING THORACIC AORTA IN PIGS
    AADAHL, P
    AAKHUS, S
    STROMHOLM, T
    SOETHER, OD
    MYHRE, HO
    EUROPEAN SURGICAL RESEARCH, 1995, 27 (05) : 323 - 331
  • [39] CARDIAC-OUTPUT MEASUREMENT - LACK OF AGREEMENT BETWEEN THERMODILUTION AND THORACIC ELECTRIC BIOIMPEDANCE IN 2 CLINICAL SETTINGS
    ATALLAH, MM
    DEMAIN, AD
    JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) : 182 - 185
  • [40] EFFECT OF MEASUREMENT ERRORS ON CARDIAC-OUTPUT CALCULATED WITH O-2 AND MODIFIED CO2 FICK METHODS
    MAHUTTE, CK
    JAFFE, MB