ARTERIOVENOUS DIFFERENCES IN PCO2 AND CARDIAC-OUTPUT DURING CPR IN THE DOG

被引:13
作者
SATO, S
OKUBO, N
SATSUMAE, T
KUMAGAI, M
YAMAMOTO, S
NAKAYAMA, H
TAGUCHI, N
机构
[1] Department of Anesthesiology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba-shi, Ibaraki
关键词
CPR; ARTERIOVENOUS DIFFERENCES (AVD) OF CO2; END-TIDAL CO2; CARDIAC OUTPUT;
D O I
10.1016/0300-9572(94)90039-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Using 14 mongrel dogs, we investigated the correlation between arteriovenous differences of PCO2 (AVD-CO2) and cardiac output (CO) during CPR. Ventricular fibrillation was induced by an electrical current and the respirator was stopped for 5 min. Cardiopulmonary resuscitation (CPR) was performed during the next 10 min and CO was measured with simultaneous arterial and venous blood gas analysis. CO was measured 26 times during CPR. The animals were divided into two groups according to the values of CO during CPR: low-CO group (CO < 0.3 1/min) and high-CO group (CO greater-than-or-equal-to 0.3 l/min). AVD-CO2 in the low CO group was 39.8 +/- 5.7 mmHg and that of the high group was 27.4 +/- 14.8 mmHg (mean +/- S.D., P < 0.05). In conclusion, AVD-CO2 showed an inverse result with the degree of CO during CPR.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] MEASUREMENT OF CARDIAC-OUTPUT BY THE THERMODILUTION METHOD DURING LEFT THORACOTOMY IN THE LATERAL POSITION IN THE DOG
    LANDAIS, A
    MORIN, JP
    ROCHE, A
    CORNEC, C
    SANSOY, N
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (02) : 158 - 161
  • [2] ALPHA-ADRENERGIC REGULATION OF SPLANCHNIC VOLUME AND CARDIAC-OUTPUT IN THE DOG
    BELL, L
    HENNECKEN, J
    ZARET, BL
    RUTLEN, DL
    ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 138 (03): : 321 - 329
  • [3] ARTERIAL PULSE CONTOUR ANALYSIS TRENDING OF CARDIAC-OUTPUT - HEMODYNAMIC MANIPULATIONS DURING CEREBRAL ARTERIOVENOUS MALFORMATION RESECTION
    WEISSMAN, C
    ORNSTEIN, EJ
    YOUNG, WL
    JOURNAL OF CLINICAL MONITORING, 1993, 9 (05): : 347 - 353
  • [4] INFLUENCE OF SPLANCHNIC INTRAVASCULAR VOLUME CHANGES ON CARDIAC-OUTPUT DURING MUSCARINIC RECEPTOR STIMULATION IN THE ANESTHETIZED DOG
    MORSE, MA
    BELL, L
    RUTLEN, DL
    ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 138 (03): : 331 - 336
  • [5] CARDIAC-OUTPUT DURING LIQUID (PERFLUOROCARBON) BREATHING IN NEWBORN PIGLETS
    CURTIS, SE
    FUHRMAN, BP
    HOWLAND, DF
    DEFRANCISIS, M
    MOTOYAMA, EK
    CRITICAL CARE MEDICINE, 1991, 19 (02) : 225 - 230
  • [6] CARDIAC-OUTPUT AND REGIONAL HEMODYNAMICS DURING RECURRENT SEIZURES IN RATS
    KREISMAN, NR
    GAUTHIERLEWIS, ML
    CONKLIN, SG
    VOSS, NF
    BARBEE, RW
    BRAIN RESEARCH, 1993, 626 (1-2) : 295 - 302
  • [7] IMPROVEMENT IN CARDIAC-OUTPUT DURING AIRWAY PRESSURE RELEASE VENTILATION
    FALKENHAIN, SK
    REILLEY, TE
    GREGORY, JS
    CRITICAL CARE MEDICINE, 1992, 20 (09) : 1358 - 1360
  • [8] Venoarterial PCO2 gradient does not correlate with cardiac output, base excess and arterial lactate concentration in septic shock patients
    A Toledo Maciel
    D Teixeira Noritomi
    A Machado
    LCP Azevedo
    VR Pizzo
    A Carlos Kajdacsy-Balla Amaral
    M Park
    Critical Care, 8 (Suppl 1):
  • [9] SIMULTANEOUS ASSESSMENT OF CARDIAC-OUTPUT WITH PULSED DOPPLER AND ELECTROMAGNETIC FLOWMETERS DURING CARDIAC STIMULATION
    GROHS, JG
    HUBER, S
    RABERGER, G
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1993, 30 (01) : 33 - 38
  • [10] THE EFFECT OF A MEAL ON CARDIAC-OUTPUT IN MAN AT REST AND DURING MODERATE EXERCISE
    WAALER, BA
    ERIKSEN, M
    JANBU, T
    ACTA PHYSIOLOGICA SCANDINAVICA, 1990, 140 (02): : 167 - 173