GALLIUM-ARSENIDE CHARGE-SENSITIVE PREAMPLIFIER FOR OPERATION IN A WIDE LOW-TEMPERATURE RANGE

被引:13
作者
ALESSANDRELLO, A
BROFFERIO, C
CAMIN, DV
GIULIANI, A
PESSINA, G
PREVITALI, E
机构
[1] IST NAZL FIS NUCL,I-20133 MILAN,ITALY
[2] UNIV MILAN,I-20133 MILAN,ITALY
关键词
D O I
10.1016/0168-9002(90)91513-B
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A charge-sensitive preamplifier for temperature operation between 1 and 120 K has been developed and evaluated. It uses double-gate GaAs MESFETs selected for their low 1/f{hook} noise. These devices are operated with both gates interconnected emulating single-gate MESFETs of double gate-length, obtaining in this way a value for Af{hook}, the coefficient of the 1/f{hook} noise spectral power density, of 1.7 × 10-13 V2 at 77 K and 3.8 × 10-14 V2 at 4 K. The latter is one fourth the value exhibited by the original device before modification and two orders of magnitude less than the value measured at 300 K. At the optimum bias operating point device transconductance is 6 mA/V, input capacitance is less than 5 pF and the power dissipation 360 μW. The circuit configuration consists of a double-cascade loaded with a bootstrapped current source. In this way, a high gain-bandwidth product is obtained despite of the low dynamic output resistance, 3000 Ω, exhibited by the MESFETs at the operating point. Equivalent noise charge was measured for detector capacitances up to 35 pF. Using a semi-Gaussian weighting function minimum values of 58 and 20 rmse- at 77 and 4 K, respectively, were determined. Noise slopes are 4.68 and 3.64 e-/pF at 1 μs shaping time for 77 and 4 K, respectively. A rise time of 20 ns was measured at the receiving-end of a 1 m length 50 Ω coaxial cable terminated at sending-end, when detector capacitance was CD = 35 pF. The total power dissipation of the preamplifier is less than 10 mW. © 1990.
引用
收藏
页码:426 / 437
页数:12
相关论文
共 22 条
[1]   THERMAL DETECTION OF PARTICLES USING BOLOMETRIC DEVICES [J].
ALESSANDRELLO, A ;
CAMIN, DV ;
FIORINI, E ;
GIULIANI, A ;
PESSINA, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 264 (01) :93-97
[2]  
ALESSANDRELLO A, 1987, P WORKSHOP LOW TEMPE, P122
[3]  
ALESSANDRELLO A, 1989, IEEE T NUCL SCI, V37, P471
[4]  
ALESSANDRELLO A, 1988, 2ND P EUR WORKSH LOW, P403
[5]   LOW-NOISE PREAMPLIFIERS FOR 1K OPERATION USING GALLIUM-ARSENIDE MESFETS OF VERY LOW 1/F NOISE [J].
CAMIN, DV ;
PESSINA, G ;
PREVITALI, E ;
RANUCCI, G .
CRYOGENICS, 1989, 29 (08) :857-862
[6]   A 1-K FRONT-END ELECTRONICS FOR A CRYOGENIC BOLOMETRIC DETECTOR [J].
CAMIN, DV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (01) :204-210
[7]  
CAMIN DV, GEOMETRY DEPENDENCE
[8]  
CAMIN DV, 1988, P E MRS S SUPERCONDU, P217
[9]  
CAMIN DV, Patent No. 20610689
[10]   LOW FREQUENCY NOISE IN MOS TRANSISTORS .2. EXPERIMENTS [J].
CHRISTEN.S ;
LUNDSTRO.I .
SOLID-STATE ELECTRONICS, 1968, 11 (09) :813-&