Longitudinal volume analysis from computed tomography: Reproducibility using adrenal glands as surrogate tumors

被引:3
|
作者
Prionas, Nicolas D. [1 ]
Gillen, Marijo A. [1 ]
Boone, John M. [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Ellison Ambulat Care Ctr, Dept Radiol, Sacramento, CA 95817 USA
关键词
Computed tomography; volumetric; reproducibility;
D O I
10.4103/0971-6203.62130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aims to determine the precision (reproducibility) of volume assessment in routine clinical computed tomography (CT) using adrenal glands as surrogate tumors. Seven patients at our institution were identified retrospectively as having received numerous abdominal CT scans (average 13.1, range 5 to 20). The adrenal glands were used as surrogate tumors, assuming no actual volume change. Left and right adrenal gland volumes were assessed by hand segmentation for each patient scan. Over 1240 regions of interest were outlined in total. The reproducibility, expressed as the coefficient of variation (COV), was used to characterize measurement precision. The average volumes were 5.9 and 4.5 cm(3) for the left and right adrenal gland, respectively, with COVs of 17.8% and 18.9%, respectively. Using one patients data (20 scans) as an example surrogate for a spherical tumor, it was calculated that a 13% change in volume (4.2% change in diameter) could be determined with statistical significance at P=0.05. For this case, cursor positioning error in linear measurement of object size, by even 1 pixel on the CT image, corresponded to a significant change in volume (P=0.05). The precision of volume determination was dependent on total volume. Precision improved with increasing object size (r(2) =0.367). Given the small dimensions of the adrenal glands, the -18% COV is likely to be a high estimate compared to larger tumors. Modern CT scanners working with thinner sections (i.e. < 1 mm) are likely to produce better measurement precision. The use of volume measurement to quantify changing tumor size is supported as a more precise metric than linear measurement.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [41] Repeatability and Reproducibility Assessment of a PolyJet Technology Using X-ray Computed Tomography
    Pilipovic, Ana
    Barsic, Gorana
    Katic, Marko
    Havstad, Maja Rujnic
    APPLIED SCIENCES-BASEL, 2020, 10 (20): : 1 - 14
  • [42] Computed tomography of the abdomen of calves during the first 105 days of life: III. Urinary tract and adrenal glands
    Braun, U.
    Schnetzler, C.
    Augsburger, H.
    Bettschart, R.
    Ohlerth, S.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2014, 156 (05): : 237 - 247
  • [43] Normal pancreatic volume assessment using abdominal computed tomography volumetry
    Li, Lu
    Wang, Shuang
    Wang, Fei
    Huang, Guo-ning
    Zhang, Dong
    Wang, Guang-xian
    MEDICINE, 2021, 100 (34) : E27096
  • [44] Quantitative Analysis of the Characteristics of Sacral Giant Cell Tumors Using Contrast-Enhanced Computed Tomography
    Yang, Jun
    Li, Qinqing
    IRANIAN JOURNAL OF RADIOLOGY, 2019, 16 (01)
  • [45] Diagnosis of hepatic tumors with texture analysis in nonenhanced computed tomography images
    Huang, YL
    Chen, JH
    Shen, WC
    ACADEMIC RADIOLOGY, 2006, 13 (06) : 713 - 720
  • [46] Using deep learning to distinguish malignant from benign parotid tumors on plain computed tomography images
    Hu, Ziyang
    Wang, Baixin
    Pan, Xiao
    Cao, Dantong
    Gao, Antian
    Yang, Xudong
    Chen, Ying
    Lin, Zitong
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [47] Computed tomographic histogram analysis in the diagnosis of lipid-poor adenomas: Comparison to adrenal washout computed tomography
    Jhaveri, Kartik S.
    Lad, Shilpa V.
    Haider, Masoom A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) : 513 - 518
  • [48] Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDIvol)
    Anders Svensson
    Jonas Björk
    Kerstin Cederlund
    Peter Aspelin
    Ulf Nyman
    Torkel B. Brismar
    European Radiology, 2014, 24 : 1959 - 1963
  • [49] Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur
    Kobayashi, H.
    Aratake, M.
    Akamatsu, Y.
    Mitsugi, N.
    Taki, N.
    Saito, T.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (08) : 885 - 890
  • [50] QUANTIFICATION OF CORONARY-ARTERY CALCIFICATION USING ULTRAFAST COMPUTED-TOMOGRAPHY - REPRODUCIBILITY OF MEASUREMENTS
    KAJINAMI, K
    SEKI, H
    TAKEKOSHI, N
    MABUCHI, H
    CORONARY ARTERY DISEASE, 1993, 4 (12) : 1103 - 1108