Longitudinal volume analysis from computed tomography: Reproducibility using adrenal glands as surrogate tumors

被引:3
|
作者
Prionas, Nicolas D. [1 ]
Gillen, Marijo A. [1 ]
Boone, John M. [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Ellison Ambulat Care Ctr, Dept Radiol, Sacramento, CA 95817 USA
关键词
Computed tomography; volumetric; reproducibility;
D O I
10.4103/0971-6203.62130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aims to determine the precision (reproducibility) of volume assessment in routine clinical computed tomography (CT) using adrenal glands as surrogate tumors. Seven patients at our institution were identified retrospectively as having received numerous abdominal CT scans (average 13.1, range 5 to 20). The adrenal glands were used as surrogate tumors, assuming no actual volume change. Left and right adrenal gland volumes were assessed by hand segmentation for each patient scan. Over 1240 regions of interest were outlined in total. The reproducibility, expressed as the coefficient of variation (COV), was used to characterize measurement precision. The average volumes were 5.9 and 4.5 cm(3) for the left and right adrenal gland, respectively, with COVs of 17.8% and 18.9%, respectively. Using one patients data (20 scans) as an example surrogate for a spherical tumor, it was calculated that a 13% change in volume (4.2% change in diameter) could be determined with statistical significance at P=0.05. For this case, cursor positioning error in linear measurement of object size, by even 1 pixel on the CT image, corresponded to a significant change in volume (P=0.05). The precision of volume determination was dependent on total volume. Precision improved with increasing object size (r(2) =0.367). Given the small dimensions of the adrenal glands, the -18% COV is likely to be a high estimate compared to larger tumors. Modern CT scanners working with thinner sections (i.e. < 1 mm) are likely to produce better measurement precision. The use of volume measurement to quantify changing tumor size is supported as a more precise metric than linear measurement.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 50 条
  • [1] Reproducibility of trabecular structure analysis using flat-panel volume computed tomography
    Arnold C. Cheung
    Miriam A. Bredella
    Ma’moun Al Khalaf
    Michael Grasruck
    Christianne Leidecker
    Rajiv Gupta
    Skeletal Radiology, 2009, 38 : 1003 - 1008
  • [2] Reproducibility of trabecular structure analysis using flat-panel volume computed tomography
    Cheung, Arnold C.
    Bredella, Miriam A.
    Al Khalaf, Ma'moun
    Grasruck, Michael
    Leidecker, Christianne
    Gupta, Rajiv
    SKELETAL RADIOLOGY, 2009, 38 (10) : 1003 - 1008
  • [3] Reproducibility assessment of Delaire cephalometric analysis using reconstructions from computed tomography
    Debelmas, A.
    Ketoff, S.
    Lanciaux, S.
    Corre, P.
    Friess, M.
    Khonsari, R. H.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2020, 121 (01) : 35 - 39
  • [4] Computed tomography measurements of normal adrenal glands in Indian population
    Aggarwal, Neeti
    Bhoil, Rohit
    Sharma, Sanjiv
    Singh, Surya Pratap
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2019, 68 (01) : 23 - 26
  • [5] Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies
    Stella-Lida Papadopoulou
    Hector M. Garcia-Garcia
    Alexia Rossi
    Chrysafios Girasis
    Anoeshka S. Dharampal
    Pieter H. Kitslaar
    Gabriel P. Krestin
    Pim J. de Feyter
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1095 - 1104
  • [6] Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies
    Papadopoulou, Stella-Lida
    Garcia-Garcia, Hector M.
    Rossi, Alexia
    Girasis, Chrysafios
    Dharampal, Anoeshka S.
    Kitslaar, Pieter H.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) : 1095 - 1104
  • [7] Interscan reproducibility of computed tomography derived coronary plaque volume measurements
    Iraqi, Nadia
    Mortensen, Martin Bodtker
    Sand, Niels Peter Ronnow
    Busk, Martin
    Grove, Erik Lerkevang
    Dey, Damini
    Pedersen, Kamilla Bech
    Kanstrup, Helle
    Pedersen, Alexandra Uglebjerg
    Madsen, Kristian Taekker
    Parner, Erik
    Jensen, Jesper Moller
    Norgaard, Bjarne Linde
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (06) : 583 - 592
  • [8] A study on the reproducibility by computed tomography (CT) using a phantom
    Jae-Hyock Choi
    Jae-Hwan Cho
    Seon-Yeob Lee
    Cheol-Soo Park
    Journal of the Korean Physical Society, 2013, 63 : 1222 - 1227
  • [9] Classification of Liver Tumors from Computed Tomography Using NRSVM
    Priyadarsini, S.
    Tavera Romero, Carlos Andres
    Mrunalini, M.
    Rao, Ganga Rama Koteswara
    Sengan, Sudhakar
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2022, 33 (03) : 1517 - 1530
  • [10] A study on the reproducibility by computed tomography (CT) using a phantom
    Choi, Jae-Hyock
    Cho, Jae-Hwan
    Lee, Seon-Yeob
    Park, Cheol-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (06) : 1222 - 1227