MEASUREMENT OF CONCENTRATIONS OF RADON AND ITS DAUGHTERS IN INDOOR ATMOSPHERE USING CR-39 NUCLEAR TRACK DETECTOR

被引:7
|
作者
FARID, SM
机构
[1] Department of Physics, University of Swaziland, Kwaluseni, Swaziland
来源
NUCLEAR TRACKS AND RADIATION MEASUREMENTS | 1993年 / 22卷 / 1-4期
关键词
NUCLEAR TRACK DETECTOR; CALIBRATION FACTOR; INDOOR RADON; THORON; PAEE; EFFECTIVE DOSE EQUIVALENT;
D O I
10.1016/0969-8078(93)90079-J
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper presents the results of the measurements of indoor Rn-222 and daughter levels in houses of different types located in different parts of Bangladesh. The passive time-integrated method of using a solid state nuclear track detector (CR-39) was employed for measuring both the Rn-222 gas concentration as well as the potential al pha energy exposure (PAEE) level from the short lived daughters of Rn-222. The Rn-222 concentration from cup exposure and the PAEE from the bare exposure were obtained directly from the track density using calibration curves. A total of 275 exposures were made in the bare mode in 15 locations and 71 exposures in the cup mode in 6 locations. The geometric mean PAEE level obtained is 9.5 mWL with a geometric standard deviation of 1.9. The corresponding value for Rn-222 concentration are 61.3 Bq.m-3 and 2.4. The total data was collected over a period of one and a half years. The monthly variation of the geometric mean of PAEE is also shown. The annual effective dose equivalent has been estimated for each location by using the conversion factor of 9 mSv per WLM as obtained from ICRP-50. The average PAEE level obtained from the total data is below the intervention level as suggested by US EPA. However, the individual averages for each location show that in 8 out of 15 locations intervention may be considered and in others no intervention is called for. The Rn-222 concentrations at the seven locations are equal or less than the equilibrium equivalent Rn-222 concentration value as suggested by EPA. Attempts have also been made to see the variation in the PAEE levels according to different type of construction material used for the houses.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 50 条
  • [31] Developing a radon monitor for simultaneous measurement of Rn-222 and Rn-220 with less influence of humidity based on electrostatic collection and CR-39 detector
    Fan, Zhongkai
    Shan, Jian
    Lin, Fen
    Hu, Tao
    Mo, Yixiang
    Xie, Ruomei
    Yuan, Shuai
    Liu, Shuaibin
    Li, Huiying
    Yi, Haibo
    Sun, Jiale
    Wu, Jiulin
    Liu, Zhipeng
    Chen, Linquan
    Yuan, Hongzhi
    Tan, Yanliang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1052
  • [32] Macro-autoradiographs of alpha emitters in environmental materials observed with solid-state track detector CR-39
    Mori, Chizuo
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2013, 50 (09) : 891 - 897
  • [33] Nationwide survey of radon levels in indoor workplaces in Mexico using Nuclear Track Methodology
    Espinosa, G.
    Golzarri, J. I.
    Angeles, A.
    Griffith, R. V.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 1051 - 1054
  • [34] Measurement of therapeutic 12C beam in a water phantom using CR-39
    Yang, Shiyan
    Zhao, Jingfang
    Zhuo, Weihai
    Shen, Hao
    Chen, Bo
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (02) : 279 - 290
  • [35] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [36] DETERMINATION OF SOIL GAS RADON CONCENTRATION FROM SOME LOCATIONS OF GEDARIF TOWN, SUDAN, BY USING CR-39
    Elzain, Abd-Elmoniem Ahmed
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (01): : 85 - 90
  • [37] Response of the CR39 nuclear track detector to relativistic Si14+ heavy ions
    Kumar, Ashavani
    Kumar, Khanesh
    Singh, N. P.
    ASIAN JOURNAL OF CHEMISTRY, 2006, 18 (05) : 3418 - 3421
  • [38] Study on the tracks in a nuclear track detector (CR39) for detection of laser-induced charged particles
    Lee, Ji Young
    Jo, Jae Heung
    Park, Seong Hee
    Lee, Kitae
    Lee, Yong Woo
    Yea, Kwon-Hae
    Cha, Yong Ho
    Jeong, Young Uk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (01) : 426 - 430
  • [39] Preliminary applications carried out in a new-build radon chamber using CR-39 detectors inside non-commercial diffusion chambers
    Rojas, J. J.
    Lopez, M. E.
    Perez, B.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [40] MEASUREMENT OF INDOOR RADON, THORON AND THEIR PROGENY LEVELS IN DWELLINGS OF AMBALA DISTRICT, HARYANA, NORTHERN INDIA USING SOLID STATE NUCLEAR TRACK DETECTORS
    Mehta, Vimal
    Singh, S. P.
    Chauhan, R. P.
    Mudahar, G. S.
    ROMANIAN JOURNAL OF PHYSICS, 2014, 59 (7-8): : 834 - 845