UPLC-MS/MS Determination of Aceclofenac and Diclofenac in Bulk, Dosage forms and in At-line Monitoring of Aceclofenac Synthesis

被引:7
作者
El-Bagary, Ramzia I. [1 ]
Azzazy, Hassan M. E. [2 ]
ElKady, Ehab F. [1 ]
Farouk, Faten [3 ]
机构
[1] Cairo Univ, Fac Pharm, Pharmaceut Chem Dept, Cairo, Egypt
[2] Amer Univ Cairo, Sch Sci & Engn, Chem Dept, Cairo, Egypt
[3] Ahram Canadian Univ, Fac Pharm, Pharmaceut Chem Dept, Giza, Egypt
关键词
Aceclofenac; diclofenac; synthetic impurities; UPLC-MS/MS; process analytical technology;
D O I
10.9734/BJPR/2014/5676
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: The derivatization product of diclofenac (DCL), aceclofenac (ACL), is a non-steroidal anti-inflammatory drug (NSAID) which causes faster and extended action with reduced gastrointestinal (GI) inflammation. The detection of DCL in ACL bulk and pharmaceutical products indicates incomplete synthesis and hydrolysis. In this article we have developed a UPLC-MS/MS method for analysis of ACL and DCL. The method was designed as an at-line monitoring tool for process analytical technology (PAT) application to ACL synthesis. The method was also applied for analysis of ACL and DCL in bulk and tablets. Methodology: Isocratic elution was performed on a UPLC C18 column (2.1 x 50 mm, 1.7 mu m) using a mobile phase consisting of acetonitrile, water and formic acid (80:20:0.5, v/v/v). Flow rate was 0.2 mL/min and total run time was 1 min. Auto-sampler temperature was maintained at 5 degrees C to prevent any further degradation of ACL. Electrospray positive ionization (ESI +Ve) in multiple-reaction monitoring mode (MRM) was used for the simultaneous determination of ACL and DCL. Monitoring was performed at [M+H](+) 354.23: 250.09 and 296.13:250.1 m/z; respectively. The method was validated according to ICH guidelines Q2(R1). Results: The linearity range was 20 - 3000 ng/mL for both drugs. The developed method was accurate and precise (RSD<2%) for the determination of ACL and DCL in single solution (99.65 +/- 1.33 and 100.37 +/- 1.02 for ACL and DCL; respectively) and laboratory prepared mixtures (101.01 +/- 1.07 and 100.45 +/- 1.54 for ACL and DCL; respectively). The method was applied to Bristaflam (R) and Cataflam (R) tablets and the recovery was 100.95 +/- 0.18 and 99.15 +/- 0.62; respectively. The average recovery from reaction mixture was101.21 +/- 0.06 and 98.89 +/- 0.64 for ACL and DCL; respectively. Conclusion: The proposed UPLC-MS/MS method is valid for at-line monitoring of ACL and DCL during PAT application to ACL synthesis and drug determination in bulk and tablets.
引用
收藏
页码:1311 / 1331
页数:21
相关论文
共 37 条
[1]  
Aderibigbe SA, 2012, ACTA POL PHARM, V69, P203
[2]  
[Anonymous], 2005, J ECLET QUIM, DOI DOI 10.1590/S0100-46702005000100004
[3]  
[Anonymous], 2005, INT C HARM TECHN REQ
[4]  
British pharmacopoeia, 2010, BRIT PHARMACOPOEIA
[5]  
Chethana BK, 2012, IND ENG CHEM RES, V1
[6]   Determination of Diclofenac on a Dysprosium Nanowire-Modified Carbon Paste Electrode Accomplished in a Flow Injection System by Advanced Filtering [J].
Daneshgar, Parandis ;
Norouzi, Parviz ;
Ganjali, Mohammad Reza ;
Dinarvand, Rasoul ;
Moosavi-Movahedi, Ali Akbar .
SENSORS, 2009, 9 (10) :7903-7918
[7]   Spectrophotometric determination of diclofenac in pharmaceutical preparations [J].
de Souza, RL ;
Tubino, M .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (05) :1068-1073
[8]  
Dockner T, 1984, Process for the preparation of 1(2- hydroxyethyl)- 2- methyl- 5- nitroimidazole of high purity, Patent No. 0150407
[9]   Stability-indicating spectrophotometric and densitometric methods for determination of aceclofenac [J].
El-Saharty, YS ;
Refaat, M ;
El-Khateeb, SZ .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2002, 28 (05) :571-582
[10]  
Emami J, 2007, DARU, V15, P132