A TRANSMISSION-LINE FOR PLASMA SCATTERING MEASUREMENTS WITH A SUBMILLIMETER-WAVE GYROTRON

被引:2
|
作者
OGAWA, I
IDEHARA, T
IBE, H
KAWAHATA, K
KASPAREK, W
机构
[1] FUKUI UNIV,FAC ENGN,DEPT APPL PHYS,FUKUI 910,JAPAN
[2] NATL INST FUS SCI,NAGOYA,AICHI 46401,JAPAN
[3] UNIV STUTTGART,INST PLASMAFORSCH,D-70569 STUTTGART,GERMANY
来源
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES | 1994年 / 15卷 / 10期
关键词
TRANSMISSION LINE; SUBMILLIMETER WAVE GYROTRON; PLASMA SCATTERING MEASUREMENT;
D O I
10.1007/BF02096886
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A transmission system has been designed to produce a high intensity (similar to 100 W) and high quality (well-collimated and high purity) beam in the submillimeter wave range (f=354 GHz). Calculations using the Huygens equation for scalar diffraction show that this system can produce a high quality beam. The final goal is to apply it to scattering measurements of density fluctuations driven by instability and wave propagation during ion cyclotron resonance heating in the Compact Helical System (CHS) in the National Institute for Fusion Science at Nagoya. It will provide a high S/N ratio and high spatial and wave number resolution.
引用
收藏
页码:1587 / 1602
页数:16
相关论文
共 50 条
  • [1] DEVELOPMENT OF SUBMILLIMETER-WAVE GYROTRON FOR PLASMA DIAGNOSTICS
    SHIMIZU, Y
    MAKINO, S
    ICHIKAWA, K
    IDEHARA, T
    OGAWA, I
    FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 335 - 340
  • [2] Frequency modulation in a submillimeter-wave Gyrotron
    Idehara, T
    Pereyaslavets, M
    Nishida, N
    Yoshida, K
    Ogawa, I
    PHYSICAL REVIEW LETTERS, 1998, 81 (09) : 1973 - 1976
  • [3] MODE COOPERATION IN A SUBMILLIMETER-WAVE GYROTRON
    IDEHARA, T
    SHIMIZU, Y
    PHYSICS OF PLASMAS, 1994, 1 (10) : 3145 - 3147
  • [4] SUBMILLIMETER-WAVE HARMONIC GYROTRON EXPERIMENT
    SPIRAHAKKARAINEN, S
    KREISCHER, KE
    TEMKIN, RJ
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1990, 18 (03) : 334 - 342
  • [5] LONG-PULSE OPERATION OF A SUBMILLIMETER-WAVE GYROTRON AND ITS APPLICATION TO PLASMA SCATTERING MEASUREMENT
    OGAWA, I
    YOSHISUE, K
    IBE, H
    IDEHARA, T
    KAWAHATA, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (05): : 1788 - 1789
  • [6] Application of the gyrotron FUII submillimeter wave radiation source to plasma scattering measurements
    Idehara, T
    Ogawa, I
    Kawahata, K
    Iguchi, H
    Matsuoka, K
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2004, 25 (11): : 1567 - 1579
  • [7] Submillimeter-wave large-orbit gyrotron
    Bratman V.L.
    Kalynov Yu.K.
    Manuilov V.N.
    Samsonov S.V.
    Radiophysics and Quantum Electronics, 2005, 48 (10-11) : 731 - 736
  • [8] A sampled-line reflectometer for submillimeter-wave measurements
    Ülker, S
    Weikle, RM
    2002 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2002, : 1677 - 1680
  • [9] A quasi-optical transmission line for plasma scattering measurements using a submillimetre wave gyrotron
    Ogawa, I
    Sakai, A
    Idehara, T
    Kawahata, K
    Kasparek, W
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1997, 83 (05) : 635 - 644
  • [10] Application of the Gyrotron FU II Submillimeter Wave Radiation Source to Plasma Scattering Measurements
    T. Idehara
    I. Ogawa
    K. Kawahata
    H. Iguchi
    K. Matsuoka
    International Journal of Infrared and Millimeter Waves, 2004, 25 : 1567 - 1579