LONG-TERM RESPONSE OF AN INTEGRATED CARBON-PASTE BASED GLUCOSE BIOSENSOR

被引:26
作者
KULYS, J [1 ]
HANSEN, HE [1 ]
机构
[1] NOVO NORDISK AS,DK-3400 HILLEROD,DENMARK
关键词
BIOSENSORS; CARBON PASTE; GLUCOSE SENSOR;
D O I
10.1016/0003-2670(94)00513-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor containing integrated reference, auxiliary and two carbon paste based bioelectrodes shows linear calibration graphs for glucose concentrations > 16 mM. The biosensor response is performed on a renovated surface at an electrode potential of 60-80 mV; the capacity of the biosensor is 100 measurements. The long-term response of the biosensor relies on a glucose oxidase stability that depends on the structure of oil, water activity and stabilizer. The response of the biosensors containing silicone oil and stabilized glucose oxidase hardly changes during a period of three months at 35 degrees C and a relative humidity of 75%.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 48 条
[1]   LONG-TERM OPERATIONAL STABILITY OF A MIXED GLUCOSE OXIDASE-REDOX MEDIATOR-CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM ;
PATRIARCHE, GJ ;
KAIFER, AE .
ANALYTICAL LETTERS, 1991, 24 (08) :1293-1315
[2]   CHARACTERIZATION OF MIXED ENZYME-MEDIATOR-CARBON PASTE ELECTRODES [J].
AMINE, A ;
KAUFFMANN, JM ;
GUILBAULT, GG ;
BACHA, S .
ANALYTICAL LETTERS, 1993, 26 (07) :1281-1299
[3]  
AMINE A, 1989, 2ND WORKSH BIOM ENG, P11
[4]   BIOAMPEROMETRIC SENSORS FOR PHENOL BASED ON CARBON PASTE ELECTRODES [J].
BONAKDAR, M ;
VILCHEZ, JL ;
MOTTOLA, HA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 266 (01) :47-55
[5]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[6]  
BUCHRASMUSSEN T, 1992, Patent No. 7263
[7]  
COLIN FJ, 1990, Patent No. 10861
[8]   REAGENTLESS CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE BASED ON A PHENOTHIAZINE POLYMER DERIVATIVE AND YEAST ALCOHOL-DEHYDROGENASE FOR THE ANALYSIS OF ETHANOL [J].
DOMINGUEZ, E ;
LAN, HL ;
OKAMOTO, Y ;
HALE, PD ;
SKOTHEIM, TA ;
GORTON, L ;
HAHNHAGERDAL, B .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) :229-237
[9]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[10]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30