ANION-EXCHANGE CHROMATOGRAPHY ON SELECTED SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS

被引:4
|
作者
SECREAST, SL
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 544卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)83980-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An unexpected retention of nitrate was observed on a Zorbax Rx C-8 high-performance liquid chromatographic column suggesting an anion-exchange retention mechanism. The ability of the column to be an anion exchanger was investigated using aqueous phosphoric and acetic acid mobile phases. For comparison Nucleosil C-8 and Zorbax C-8 columns were also examined. Significant retention and separation of anions was achieved on the Zorbax Rx C-8, to some extent on the Nucleosil C-8, but not on the Zorbax C-8. Taking advantage of the unusual anion-exchange property, the Zorbax Rx C-8 column was used to simultaneously chromatograph the amine plus counter-anion components of some research pharmaceutical salts by a mixed-mode reversed-phase anion-exchange mechanism.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 50 条
  • [41] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF FENTANYL HOMOLOGS AND ANALOGS
    LURIE, IS
    ALLEN, AC
    ISSAQ, HJ
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (03): : 463 - 473
  • [42] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CARBARYL IN POSTMORTEM SPECIMENS
    DUCK, BJ
    WOOLIAS, M
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1985, 9 (04) : 177 - 179
  • [43] A REVERSED-PHASE INTERCALATOR COLUMN FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF OLIGONUCLEOTIDES
    DOHTSU, K
    OHMORI, K
    FUKUDA, R
    TAKENAKA, S
    TAKAGI, M
    ANALYTICAL SCIENCES, 1988, 4 (04) : 371 - 376
  • [44] NEW REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN FOR OLIGONUCLEOTIDE SEPARATION
    MORIYAMA, H
    KATO, Y
    JOURNAL OF CHROMATOGRAPHY, 1988, 445 (01): : 225 - 233
  • [45] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF TETRACYCLINES IN URINE AND PLASMA
    SHARMA, JP
    PERKINS, EG
    BEVILL, RF
    JOURNAL OF CHROMATOGRAPHY, 1977, 134 (02): : 441 - 450
  • [46] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ANAXIRONE IN BIOLOGICAL SPECIMENS
    SCHILCHER, RB
    YOUNG, JD
    NOWROUSIAN, MR
    HOFFMANN, B
    SCHMIDT, CG
    JOURNAL OF CHROMATOGRAPHY, 1986, 378 (01): : 248 - 253
  • [47] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF CLOSELY RELATED FUROCOUMARINS
    ERDELMEIER, CAJ
    MEIER, B
    STICHER, O
    JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT): : 456 - 460
  • [48] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NICOTINE IN PESTICIDE FORMULATIONS
    HANKS, AR
    SCHRONK, LR
    ARNST, TC
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (07): : 1087 - 1093
  • [49] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SALBUTAMOL IN RABBIT PLASMA
    KUROSAWA, N
    MORISHIMA, S
    OWADA, E
    ITO, K
    JOURNAL OF CHROMATOGRAPHY, 1984, 305 (02): : 485 - 488
  • [50] Anion-exchange behavior of several alkylsilica reversed-phase columns
    Marchand, D. H.
    Snyder, L. R.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) : 104 - 110