摘要
The main quantity of interest in radiotherapy is absorbed dose to water. For years, its determination has been obtained by indirect methods with an accuracy of 1 to 2%. A brief summary is given of the work undertaken by the national standardizing laboratories and the BIPM, to obtain better accuracy. Several methods are now available (calorimetry, ionometry, etc.) and the agreement between them is better than 1%.
引用
收藏
页码:338 / 341
页数:4
相关论文
共 50 条
  • [1] MEASUREMENTS AND CALCULATIONS OF THE ABSORBED DOSE DISTRIBUTION AROUND A CO-60 SOURCE
    TIOURINA, TB
    DRIES, WJF
    VANDERLINDEN, PM
    MEDICAL PHYSICS, 1995, 22 (05) : 549 - 554
  • [2] COMPUTATION OF ABSORBED DOSE DISTRIBUTION IN CO-60 TELETHERAPY
    CUZINO, S
    MOLDOVAN, N
    SZAKATS, M
    MATACHE, G
    REVUE ROUMAINE DE PHYSIQUE, 1975, 20 (01): : 107 - 113
  • [3] CALORIMETER AND IONIZATION-CHAMBER MEASUREMENTS OF ABSORBED DOSE IN CO-60 AND PROTON THERAPY BEAMS
    VERHEY, LJ
    MCDONALD, JC
    MA, I
    SMITH, AR
    MEDICAL PHYSICS, 1981, 8 (04) : 573 - 573
  • [4] CONSIDERATION OF FACTORS FOR DETERMINATION OF ABSORBED DOSE FROM EXPOSURE MEASUREMENTS IN BEAM OF CO-60 TELETHERAPY UNITS
    BOZOKY, L
    NAGL, J
    HAIDER, JG
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1974, 35 (1-4): : 105 - 112
  • [5] DOSE MEASUREMENTS IN OESOPHAGUS IN CO-60 ROTATION THERAPY
    MCEWAN, AC
    WHEELER, TK
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1970, 9 (06): : 618 - &
  • [6] GAP CORRECTION FOR THE CALORIMETRIC MEASUREMENT OF ABSORBED DOSE IN GRAPHITE WITH A CO-60 BEAM
    BOUTILLON, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12): : 1809 - 1821
  • [7] THE GRAPHITE CALORIMETER AS A STANDARD OF ABSORBED DOSE FOR CO-60 GAMMA-RADIATION
    PRUITT, JS
    DOMEN, SR
    LOEVINGER, R
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1981, 86 (05): : 495 - 502
  • [8] IONOMETRIC DETERMINATION OF ABSORBED DOSE TO WATER FOR CO-60 GAMMA-RAYS
    BOUTILLON, M
    PERROCHE, AM
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03): : 439 - 454
  • [9] DETERMINATION OF HIGH-LEVEL ABSORBED DOSE IN A CO-60 GAMMA-RAY FIELD WITH IONIZATION CHAMBERS
    LI, ZY
    MAO, BJ
    ZHANG, L
    RADIATION PHYSICS AND CHEMISTRY, 1995, 45 (02): : 265 - 268
  • [10] Graphite ionization chamber as an ionometric standard of absorbed dose to water for Co-60 radiation
    Szymko, M. M.
    Knyziak, A. B.
    Derlacinski, M.
    MEASUREMENT, 2022, 194