Incidence and outcome of surgical procedures after sirolimuseluting stent implantation: a report from the j-Cypher registry

被引:0
|
作者
Kimura, Takeshi [1 ]
Isshiki, Takaaki [2 ]
Hayashi, Yasuhiko [3 ]
Oshima, Shigeru [4 ]
Namura, Masanobu [5 ]
Nakashima, Hitoshi [6 ]
Kawai, Kazuya [7 ]
Sone, Takahito [8 ]
Tatami, Ryozo [9 ]
Meguro, Taiichiro [10 ]
Nobuyoshi, Masakiyo [11 ]
Mitsudo, Kazuaki [12 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Sakyo Ku, 54 Shogoin Kawahara Cho, Kyoto 6068507, Japan
[2] Teikyo Univ Hosp, Tokyo, Japan
[3] Tsuchiya Gen Hosp, Hiroshima, Japan
[4] Gunma Prefectural Cardiovasc Ctr, Gunma, Japan
[5] Kanazawa Cardiovasc Hosp, Kanazawa, Ishikawa, Japan
[6] Natl Hosp Org, Kagoshima Med Ctr, Kagoshima, Japan
[7] Chikamori Hosp, Kochi, Japan
[8] Ogaki Municipal Hosp, Ogaki, Japan
[9] Maizuru Kyosai Hosp, Maizuru, Japan
[10] Sendai Hlth Hosp, Sendai, Miyagi, Japan
[11] Kokura Mem Hosp, Kokura, Japan
[12] Kurashiki Cent Hosp, Kurashiki, Okayama, Japan
关键词
Stent; Thrombosis; Revascularization; Surgery; Aspirin;
D O I
10.1007/s12928-009-0005-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The incidence of surgical procedures after sirolimus-eluting stent (SES) implantation and, more importantly, the rate of perioperative stent thrombosis (ST) and/or other adverse events have not yet been adequately addressed. The incidence and outcome of the surgical procedures after SES implantation were prospectively evaluated in a large-scale multicenter registry of patients undergoing SES implantation. Among 12,824 patients enrolled in the registry, cumulative incidences of surgical procedures were 0.7% at 60 days, 5.1% at 1 year and 14.7% at 3 years. Surgical procedures were performed in 1,430 patients including non-coronary artery bypass graft (CABG) surgery in 1,275 patients and CABG in 189 patients. The incidences of death/myocardial infarction/ST (definite or probable) and ST (definite or probable) at 30 days after surgical procedures were 2.7 and 0.35%, respectively. Surgery performed within 60 days after SES implantation as compared with that performed beyond 60 days was associated with significantly higher incidences of death/myocardial infarction/ST (definite or probable) and ST (definite or probable) at 30 days after surgical procedures (6.4 vs. 2.5%: P = 0.02 and 2.2 vs. 0.23%: P = 0.002, respectively). Surgery within 60 days as well as hemodialysis and small body mass index were independent risk factors of death/myocardial infarction/ST (definite or probable) identified by multivariable analysis. Surgical procedures were required fairly often after SES implantation. The incidences of adverse cardiac events including ST after surgical procedures were acceptably low. Surgery within 60 days after SES implantation carried significantly higher risks as compared with those beyond 60 days.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [1] Incidence and outcome of surgical procedures after sirolimus-eluting stent implantation: a report from the j-Cypher registry
    Takeshi Kimura
    Takaaki Isshiki
    Yasuhiko Hayashi
    Shigeru Oshima
    Masanobu Namura
    Hitoshi Nakashima
    Kazuya Kawai
    Takahito Sone
    Ryozo Tatami
    Taiichiro Meguro
    Masakiyo Nobuyoshi
    Kazuaki Mitsudo
    Cardiovascular Intervention and Therapeutics, 2010, 25 (1) : 29 - 39
  • [2] Antiplatelet therapy discontinuation and stent thrombosis after sirolimus-eluting stent implantation: Five-year outcome of the j-Cypher Registry
    Yano, Mariko
    Natsuaki, Masahiro
    Morimoto, Takeshi
    Nakagawa, Yoshihisa
    Kawai, Kazuya
    Miyazaki, Shunichi
    Muramatsu, Toshiya
    Shiode, Nobuo
    Namura, Masanobu
    Sone, Takahito
    Oshima, Shigeru
    Nishikawa, Hideo
    Hiasa, Yoshikazu
    Hayashi, Yasuhiko
    Nobuyoshi, Masakiyo
    Mitsudo, Kazuaki
    Kimura, Takeshi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 : 296 - 301
  • [3] Antiplatelet therapy and long-term clinical outcome after sirolimus-eluting stent implantation: 5-year outcome of the j-Cypher registry
    Kimura, Takeshi
    Morimoto, Takeshi
    Nakagawa, Yoshihisa
    Kadota, Kazushige
    Nozaki, Yoichi
    Tada, Tomohisa
    Take, Shunsuke
    Shirota, Kinya
    Ito, Akira
    Nakashima, Hitoshi
    Fujita, Hiroshi
    Kawasaki, Tomohiro
    Inada, Tsukasa
    Nakao, Koichi
    Miyazaki, Shunichi
    Doi, Osamu
    Isshiki, Takaaki
    Nobuyoshi, Masakiyo
    Mitudo, Kazuaki
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2012, 27 (03) : 181 - 188
  • [4] Antiplatelet therapy and long-term clinical outcome after sirolimus-eluting stent implantation: 5-year outcome of the j-Cypher registry
    Takeshi Kimura
    Takeshi Morimoto
    Yoshihisa Nakagawa
    Kazushige Kadota
    Yoichi Nozaki
    Tomohisa Tada
    Shunsuke Take
    Kinya Shirota
    Akira Ito
    Hitoshi Nakashima
    Hiroshi Fujita
    Tomohiro Kawasaki
    Tsukasa Inada
    Koichi Nakao
    Shunichi Miyazaki
    Osamu Doi
    Takaaki Isshiki
    Masakiyo Nobuyoshi
    Kazuaki Mitudo
    Cardiovascular Intervention and Therapeutics, 2012, 27 (3) : 181 - 188
  • [5] Very Late Stent Thrombosis and Late Target Lesion Revascularization After Sirolimus-Eluting Stent Implantation Five-Year Outcome of the j-Cypher Registry
    Kimura, Takeshi
    Morimoto, Takeshi
    Nakagawa, Yoshihisa
    Kawai, Kazuya
    Miyazaki, Shunichi
    Muramatsu, Toshiya
    Shiode, Nobuo
    Namura, Masanobu
    Sone, Takahito
    Oshima, Shigeru
    Nishikawa, Hideo
    Hiasa, Yoshikazu
    Hayashi, Yasuhiko
    Nobuyoshi, Masakiyo
    Mitudo, Kazuaki
    CIRCULATION, 2012, 125 (04) : 584 - U111
  • [6] The incidence of late stent thrombosis after successful cypher stent implantation
    Sharifkazemi, M. B.
    Aslani, A.
    Zamirian, M.
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2007, 1 (02) : 103 - 105
  • [7] Impact of Multiple and Long Sirolimus-Eluting Stent Implantation on 3-Year Clinical Outcomes in the j-Cypher Registry
    Shirai, Shinichi
    Kimura, Takeshi
    Nobuyoshi, Masakiyo
    Morimoto, Takeshi
    Ando, Kenji
    Soga, Yoshimitsu
    Yamaji, Kyohei
    Kondo, Katsuhiro
    Sakai, Koyu
    Arita, Takeshi
    Goya, Masahiko
    Iwabuchi, Masashi
    Yokoi, Hiroyoshi
    Nosaka, Hideyuki
    Mitsudo, Kazuaki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) : 180 - 188
  • [8] Three-Year Outcomes After Sirolimus-Eluting Stent Implantation for Unprotected Left Main Coronary Artery Disease Insights From the j-Cypher Registry
    Toyofuku, Mamoru
    Kimura, Takeshi
    Morimoto, Takeshi
    Hayashi, Yasuhiko
    Ueda, Hiroaki
    Kawai, Kazuya
    Nozaki, Yoichi
    Hiramatsu, Shinichi
    Miura, Akira
    Yokoi, Yoshiaki
    Toyoshima, Shinichiro
    Nakashima, Hitoshi
    Haze, Kazuo
    Tanaka, Masaru
    Take, Shunsuke
    Saito, Shigeru
    Isshiki, Takaaki
    Mitsudo, Kazuaki
    CIRCULATION, 2009, 120 (19) : 1866 - U50
  • [9] Sirolimus-Eluting Stent Implantation for Ostial Left Anterior Descending Coronary Artery Lesions Three-Year Outcome From the j-Cypher Registry
    Kishi, Koichi
    Kimura, Takeshi
    Morimoto, Takeshi
    Namura, Masanobu
    Muramatsu, Toshiya
    Nishikawa, Hideo
    Hiasa, Yoshikazu
    Isshiki, Takaaki
    Nobuyoshi, Masakiyo
    Mitsudo, Kazuaki
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) : 362 - U127
  • [10] Comparison of Five-Year Outcome of Sirolimus-Eluting Stent Implantation for Chronic Total Occlusions Versus for Non-Chronic Total Occlusin (from the j-Cypher Registry)
    Kato, Masafumi
    Kimura, Takeshi
    Morimoto, Takeshi
    Nishikawa, Hideo
    Uchida, Fumiya
    Suzuki, Hiroyuki
    Hayashi, Yasuhiko
    Kadota, Kazushige
    Mitsudo, Kazuaki
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (09) : 1282 - 1289