INTEGRATED OPTICAL IMMUNOSENSOR FOR S-TRIAZINE DETERMINATION - REGENERATION, CALIBRATION AND LIMITATIONS

被引:48
作者
BIER, FF [1 ]
JOCKERS, R [1 ]
SCHMID, RD [1 ]
机构
[1] GESELL BIOTECHNOL FORSCH MBH,DEPT ENZYME TECHNOL,PROJECT GRP BIOSENSORS,D-38124 BRAUNSCHWEIG,GERMANY
关键词
IMMUNOSENSOR; INTEGRATED OPTICS; GRATING COUPLER; COMPETITIVE ASSAY; S-TRIAZINE;
D O I
10.1039/an9941900437
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Grating couplers, as an example of an integrated optical transducer, were investigated for label-free immunosensing in a flow-through system. The detection of pesticides by a competitive assay format was demonstrated using a triazine (terbutryn) as an example. Long-term stability and reproducibility were achieved by immobilizing the hapten, which in this instance was a derivative of the pesticide to be determined. Hence, the lifetime of the sensor does not depend on the stability of the antibody but is limited only by the quality of the immobilization. Regeneration of the sensor surface was achieved using proteinase supported by acidic washing; it was observed directly and could therefore be optimized. In consequence, calibration, usually critical in immunosensing, was possible. Non-specific binding was determined to be 10% and could be decreased by addition of bovine serum albumin. The detection limit found for terbutryn was 15 mug l-1 in the arrangement used; strategies for enhancement of sensitivity are discussed.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 19 条
[1]   OPTICAL BIOSENSORS FOR IMMUNOASSAYS - THE FLUORESCENCE CAPILLARY-FILL DEVICE [J].
BADLEY, RA ;
DRAKE, RAL ;
SHANKS, IA ;
SMITH, AM ;
STEPHENSON, PR ;
THOMAS, JDR .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) :143-160
[2]   USE OF A FIBER OPTIC IMMUNOSENSOR FOR THE DETECTION OF PESTICIDES [J].
BIER, FF ;
STOCKLEIN, W ;
BOCHER, M ;
BILITEWSKI, U ;
SCHMID, RD .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :509-512
[3]  
BOLTIEUX JL, 1989, CLIN CHEM WINSTON SA, V35, P1026
[4]   REGENERABLE FIBER-OPTIC-BASED IMMUNOSENSOR [J].
BRIGHT, FV ;
BETTS, TA ;
LITWILER, KS .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1065-1069
[5]  
GIERSCH T, 1990, Food and Agricultural Immunology, V2, P85, DOI 10.1080/09540109009354707
[6]   ENZYME IMMUNOASSAYS FOR THE DETERMINATION OF S-TRIAZINES IN WATER SAMPLES - 2 INTERLABORATORY TESTS [J].
HOCK, B .
ANALYTICAL LETTERS, 1991, 24 (04) :529-549
[7]  
HOCK B, COMMUNICATION
[8]   ENHANCEMENT OF IMMUNOASSAY SENSITIVITY BY MOLECULAR MODIFICATION OF COMPETITORS [J].
JOCKERS, R ;
BIER, FF ;
SCHMID, RD .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 163 (02) :161-167
[9]  
KUNZ RE, 1991, SENSOR ACTUAT A-PHYS, V25, P155