DETECTION OF ANTIGENS IN IMMUNE-COMPLEXES BY A DOT-BLOT ASSAY

被引:12
作者
NEZLIN, R
MOZES, E
机构
[1] Department of Chemical Immunology, The Weizmann Institute of Science, Rehovot
关键词
IMMUNE COMPLEXES; DETERMINATION OF ANTIGENS; AVIDIN; DNA; DOT BLOTTING; SYSTEMIC LUPUS ERYTHEMATOSUS;
D O I
10.1016/0022-1759(95)00113-O
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple assay is described for detection of antigens as a part of immune complexes. The complexes together with free IgG molecules are absorbed on protein A (or G)-Sepharose. The Sepharose beads are transferred to nitrocellulose membrane where all IgG including their complexes with antigens are eluted by acidic buffer directly on the surface of the membrane. The antigens immobilized on the membrane after elution are detected by corresponding labeled antibodies. The validity of the procedure was assessed by experiments with complexes of avidin and rabbit antibodies. The assay was used also for detection of DNA in immune complexes in mice with experimental systemic lupus erythematosus (SLE).
引用
收藏
页码:273 / 276
页数:4
相关论文
共 50 条
  • [31] THE EFFECTS OF IGG AND IMMUNE-COMPLEXES ON THE ENDOTOXIN-INDUCED CYTOKINE RESPONSE
    YENTIS, SM
    GOODING, RP
    RICHES, PG
    CYTOKINE, 1994, 6 (03) : 247 - 254
  • [32] COMPLEMENT ACTIVATION AND IMMUNE-COMPLEXES IN EARLY CONGENITAL HIV-INFECTION
    JARVIS, JN
    TAYLOR, H
    IOBIDZE, M
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES AND HUMAN RETROVIROLOGY, 1995, 8 (05): : 480 - 485
  • [33] RHEUMATOID FACTORS AND CIRCULATING IMMUNE-COMPLEXES IN HIV-INFECTED INDIVIDUALS
    PROCACCIA, S
    BLASIO, R
    VILLA, P
    LAZZARIN, A
    BONACINA, C
    NOVATI, R
    BINI, T
    MEMOLI, M
    IMONDI, N
    ZANUSSI, C
    AIDS, 1991, 5 (12) : 1441 - 1446
  • [34] MECHANISM OF LOCALIZATION OF IMMUNE-COMPLEXES IN NZB/W MICE WITH EARLY NEPHRITIS
    GRANHOLM, NA
    CAVALLO, T
    AUTOIMMUNITY, 1990, 8 (01) : 17 - 24
  • [35] CHOLESTEROL CRYSTALS AND IGE-CONTAINING IMMUNE-COMPLEXES IN RHEUMATOID PERICARDITIS
    VANOFFEL, JF
    DECLERCK, LS
    KERSSCHOT, IE
    CLINICAL RHEUMATOLOGY, 1991, 10 (01) : 78 - 80
  • [36] Evaluation of a novel line-blot immunoassay for the detection of antibodies to extractable nuclear antigens
    Damoiseaux, J
    Boesten, K
    Giesen, J
    Austen, J
    Tervaert, JWC
    AUTOIMMUNITY: CONCEPTS AND DIAGNOSIS AT THE CUTTING EDGE, 2005, 1050 : 340 - 347
  • [37] CLUSTERING OF NEUTROPHIL LEUKOCYTES IN SERUM - POSSIBLE ROLE OF C1Q-CONTAINING IMMUNE-COMPLEXES
    STURFELT, G
    JONSSON, H
    HELLMER, G
    SJOHOLM, AG
    CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 1993, 93 (02) : 237 - 241
  • [38] EFFECT OF IMMUNE-COMPLEXES ON ELECTROPHORETIC MOBILITY OF SHEEPS RED-BLOOD-CELLS
    KONSTANTINOVA, NA
    SAPOZHNIKOV, AM
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1990, 109 (03) : 365 - 367
  • [39] A NEW C1Q SOLID-PHASE ASSAY FOR THE DETECTION OF IGM IMMUNE-COMPLEXES - APPLICATION TO THE FOLLOW-UP OF KIDNEY GRAFT RECIPIENTS WITH RECURRENT CYTOMEGALOVIRUS-INFECTION
    BASSON, J
    TARDY, JC
    AYMARD, M
    JOURNAL OF CLINICAL & LABORATORY IMMUNOLOGY, 1990, 31 (01) : 43 - 49
  • [40] ANTISTEROID IMMUNE-COMPLEXES AND VASCULAR THROMBOSIS DURING STEROID-HORMONE THERAPY
    VANDENBRULE, F
    COIBION, M
    HENDRICK, JC
    GASPARD, UJ
    CONTRACEPTION, 1994, 49 (06) : 571 - 577