ULTRASOUND-GUIDED RENAL BIOPSY WITH BIOPSY GUN TECHNIQUE EFFICACY AND COMPLICATIONS

被引:10
作者
CHRISTENSEN, J
LINDEQUIST, S
KNUDSEN, DU
PEDERSEN, RS
机构
[1] ESBJERG CTY HOSP,DEPT DIAGNOST RADIOL,ESBJERG,DENMARK
[2] ESBJERG CTY HOSP,DEPT INTERNAL MED,DIV NEPHROL,ESBJERG,DENMARK
关键词
KIDNEY; PARENCHYMA; BIOPSY; ULTRASOUND; COMPLICATIONS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One hundred and thirty-one ultrasound-guided renal biopsies performed in 127 patients with automated spring-loaded biopsy technique were evaluated. Adequate tissue for histologic diagnosis was obtained in 92% of the procedures (94% of the patients). The mean glomerular yield was 16.8 glomeruli. Complications were seen in 21% of the patients, 18% having minor and 3% having major complications. Patients with severe hypertension had significantly more complications than the rest of the patients. The rate of complications in patients who had 3 or 4 biopsy passes was not increased compared to patients who had one or 2 biopsy passes. Thus, this study indicates that the risk of complications and the safety of the procedure is not influenced by increasing the number of biopsy passes in order to obtain representative specimens.
引用
收藏
页码:276 / 279
页数:4
相关论文
共 36 条
  • [1] ALMQUIST RD, 1979, UROL CLIN N AM, V6, P503
  • [2] COMPUTERIZED TOMOGRAPHIC ASSESSMENT OF RETROPERITONEAL HEMORRHAGE AFTER PERCUTANEOUS RENAL BIOPSY
    ALTER, AJ
    ZIMMERMAN, S
    KIRACHAIWANICH, C
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1980, 140 (10) : 1323 - 1326
  • [3] NEEDLE-BIOPSY OF RENAL-ALLOGRAFTS - COMPARISON OF 2 TECHNIQUES
    BOGAN, ML
    KOPECKY, KK
    KRAFT, JL
    HOLLADAY, AO
    FILO, RS
    LEAPMAN, SB
    THOMALLA, JV
    [J]. RADIOLOGY, 1990, 174 (01) : 273 - 275
  • [4] KIDNEY BIOPSY
    BRETLAND, PM
    HOFFBRAND, BI
    [J]. BRITISH MEDICAL JOURNAL, 1980, 281 (6240) : 619 - 619
  • [5] PERCUTANEOUS RENAL BIOPSY WITH THE USE OF REAL-TIME ULTRASOUND
    BURSTEIN, DM
    SCHWARTZ, MM
    KORBET, SM
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 1991, 11 (03) : 195 - 200
  • [6] CARAVJAL HF, 1971, TEX REP BIOL MED, V29, P253
  • [7] THE IMPORTANCE OF SAMPLE-SIZE IN THE INTERPRETATION OF THE RENAL BIOPSY
    CORWIN, HL
    SCHWARTZ, MM
    LEWIS, EJ
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 1988, 8 (02) : 85 - 89
  • [8] CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY
    COZENS, NJA
    MURCHISON, JT
    ALLAN, PL
    WINNEY, RJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) : 594 - 597
  • [9] Diaz-Buxo J A, 1975, Clin Nephrol, V4, P223
  • [10] RENAL BIOPSY - CURRENT VIEWS AND CONTROVERSIES
    GAULT, MH
    MUEHRCKE, RC
    [J]. NEPHRON, 1983, 34 (01) : 1 - 34