摘要
This three-dimensional finite element analysis first described stresses distribution in loaded posterior fixed partial dentures, then compared the influences of bone height, abutment roots number and pontic length on their displacements. Twelve mandibular (three to five unit) FDPs integrating periodontal ligaments were designed. Stresses were localized in connectors and cervical areas of abutments near the edentulous span. The main FDPs' displacements consisted of vertical translation increasing with low bone height. FDPs underwent simultaneously an anteroposterior displacement (about ten times smaller) towards the weakest abutment side. Splinted abutments affected this anteroposterior displacement. Span length was associated with small beam deflection.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 44 条
[1]  
Ante IH, 1926, MICH STATE DENT SOC, V8, P14
[2]   Relevance of the finite element method to optimize fixed partial denture design. Part I. Influence of the size of the connector on the magnitude of strain. [J].
Augereau D. ;
Pierrisnard L. ;
Barquins M. .
Clinical Oral Investigations, 1998, 2 (1) :36-39
[3]   Improved retention of anterior cantilever resin-bonded prostheses by design alteration: An experimental and finite element study [J].
Bhakta, S ;
van Noort, R ;
Cardew, G .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) :209-217
[4]  
CARTER DR, 1978, CLIN ORTHOP RELAT R, P192
[5]  
Craig R. G., 2002, RESTORATIVE DENT MAT
[6]   Viscoelastic finite element analysis of an all-ceramic fixed partial denture [J].
DeHoff, PH ;
Anusavice, KJ ;
Götzen, N .
JOURNAL OF BIOMECHANICS, 2006, 39 (01) :40-48
[7]   Loading of bone surrounding implants through three-unit fixed partial denture fixation:: a finite-element analysis based on in vitro and in vivo strain measurements [J].
Heckmann, SM ;
Karl, M ;
Wichmann, MG ;
Winter, W ;
Graef, F ;
Taylor, TD .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (03) :345-350
[8]  
KARLSSON S, 1989, SWED DENT J, V13, P185
[9]   FAILURE OF ALL-CERAMIC FIXED PARTIAL DENTURES IN-VITRO AND IN-VIVO - ANALYSIS AND MODELING [J].
KELLY, JR ;
TESK, JA ;
SORENSEN, JA .
JOURNAL OF DENTAL RESEARCH, 1995, 74 (06) :1253-1258
[10]   MATHEMATICAL-MODEL OF AN INVITRO HUMAN MANDIBLE [J].
KNOELL, AC .
JOURNAL OF BIOMECHANICS, 1977, 10 (03) :159-166