IMPROVED METHODS TO DETERMINE OPTIMAL CURRENTS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:14
|
作者
HUA, P [1 ]
WOO, EJ [1 ]
WEBSTER, JG [1 ]
TOMPKINS, WJ [1 ]
机构
[1] UNIV WISCONSIN,DEPT ELECT & COMP ENGN,MADISON,WI 53706
基金
美国国家科学基金会;
关键词
D O I
10.1109/42.192684
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Our electrical impedance tomography (EIT) system uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution. The optimal current patterns, however, are a function of the unknown resistivity distribution, thus they cannot be obtained analytically. In this paper we developed iterative methods to derive the optimal current patterns through iterative physical measurements. We also developed direct methods to first determine the resistance matrix of a resistivity distribution through a set of experimental measurements, then used the singular value decomposition (SVD) to obtain the optimal current patterns. In both the iterative and direct methods, we injected a complete set of current bases and stored the measured voltage responses. This permitted iterative reconstruction techniques to operate on the stored data without requiring lengthy data taking from the object. This reduced the effects or motion artifacts. We concluded that the direct methods have superior performance as compared to the iterative methods in both optimal current and voltage generation. We studied three sets of current bases: Fourier, diagonal, and neighboring. The Fourier-based, method produced most accurate results but required multiple current generators. The diagonal-based method produced slightly less accurate but comparable results using the simple hardware of a single current generator.
引用
收藏
页码:488 / 495
页数:8
相关论文
共 50 条
  • [1] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED CURRENTS
    GENCER, NG
    KUZUOGLU, M
    IDER, YZ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) : 338 - 350
  • [2] OPTIMAL EXPERIMENTS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    LIONHEART, W
    PIDCOCK, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 681 - 686
  • [3] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED AND INJECTED CURRENTS
    GENCER, NG
    IDER, YZ
    KUZUOGLU, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 95 - 99
  • [4] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855
  • [5] ITERATIVE RECONSTRUCTION METHODS USING REGULARIZATION AND OPTIMAL CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) : 621 - 628
  • [6] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 3 - 4
  • [7] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 : U3 - U3
  • [8] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : UA1 - UA1
  • [9] MULTIFREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RECORD, PM
    GADD, R
    VINTHER, F
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 67 - 72
  • [10] ELECTRICAL-IMPEDANCE TOMOGRAPHY - THE CONSTRUCTION AND APPLICATION TO PHYSIOLOGICAL MEASUREMENT OF ELECTRICAL-IMPEDANCE IMAGES
    BROWN, BH
    BARBER, DC
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1987, 13 (02) : 69 - 75