ANGIODYNOGRAPHY (COLOR-CODED DUPLEX SONOGRAPHY) IN THE EVALUATION OF VASCULOGENIC IMPOTENCE

被引:1
作者
STROHMAIER, WL
THOMAS, C
WILBERT, DM
BICHLER, KH
CLAUSSEN, CD
机构
[1] Departments of Urology, University of Tübingen, Medical School, Tübingen
[2] Departments of Radiology, University of Tübingen Medical School, Tübingen
关键词
ANGIODYNOGRAPHY; COLOR-CODED DUPLEX SONOGRAPHY; IMPOTENCE;
D O I
10.1159/000282189
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The penile arteries of 18 men with erectile dysfunction were examined by angiodynography (color-coded duplex sonography). Blood flow velocity was measured before and after intracavernous injection of papaverine/phentolamine. The angiodynographic findings were compared to arteriography. Normal values of peak flow velocity (after injection) were obtained from 6 men with normal arteriographic findings (deep artery > 25 cm/s, superficial artery > 30 cm/s). Angiodynography enables good imaging of the four penile arteries superior to duplex sonography. A strong correlation with the arteriographic findings could be found. Thus noninvasive angiodynography may replace penile arteriography for the routine evaluation of impotence.
引用
收藏
页码:70 / &
相关论文
共 13 条
[11]  
Merritt C.R.B., Doppler blood-flow imaging: Integrating flow with tissue data, Diagn Imag, 55, pp. 146-155, (1986)
[12]  
Kruyt R.H., Giesbers A.A.G.M., Color Doppler analysis of penile arteries in impotence, Radiology, 169, (1989)
[13]  