PATTERNS OF SKULL BASE FRACTURE - A 3-DIMENSIONAL COMPUTED TOMOGRAPHIC STUDY

被引:11
作者
ALI, QM
DIETRICH, B
BECKER, H
机构
[1] HANNOVER MED SCH,NEURORADIOL ABT,D-30623 HANNOVER,GERMANY
[2] SULTAN QABOOS UNIV,COLL MED,MASQAT,OMAN
关键词
COMPUTED TOMOGRAPHY; SKULL BASE; FRACTURES; RADIOGRAPHY;
D O I
10.1007/BF00600424
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Three-dimensional (3D) computed tomographic (CT) reconstructions were studied retrospectively in 14 patients with skull base fractures. Our aim was to assess the clarity of visualisation and pattern of these fractures. The reformations were obtained from 3 mm thick two-dimensional (2D) CT images. The 2D data stored on optical discs were retrieved and reformatted using the scanner's software. The 3D technique could demonstrate the presence of fractures as well as 2D images. It was of special value in defining the depth and extent of fractures in the floor of the cranial fossae. Undisplaced and displaced fractures could both be demonstrated. Fractures in the anterior fossa run diagonally towards the midline and then cross the cribriform plate of the ethmoid bone. Fractures of the middle fossa run obliquely anteroposterior. Fractures in the lamina papyracea and cribriform plate were difficult to reconstruct due to the the thinness of these bones and threshold definitions. The volume of the 3D block determines the angles suitable for viewing the fractures. In spite of present technical difficulties, the 3D images are of greater anatomical and diagnostic value, particularly in anterior fossa fractures. There is no additional radiation risk to the patient, since reconstructions are made from routine 2D images.
引用
收藏
页码:622 / 624
页数:3
相关论文
共 13 条
[1]   3-DIMENSIONAL CT OF THE MIDDLE-EAR AND ADJACENT STRUCTURES [J].
ALI, QM ;
ULRICH, C ;
BECKER, H .
NEURORADIOLOGY, 1993, 35 (03) :238-241
[2]  
DOLAN WC, 1988, J ORAL MAXILLOFAC SU, V46, P142
[3]   3-DIMENSIONAL COMPUTED TOMOGRAPHIC REFORMATIONS OF SELLAR AND PARA-SELLAR LESIONS [J].
GILLESPIE, JE ;
ADAMS, JE ;
ISHERWOOD, I .
NEURORADIOLOGY, 1987, 29 (01) :30-35
[4]  
GRODD W, 1987, RADIOLOGE, V27, P502
[5]   CT OF DRY SKULLS WITH CRANIOFACIAL DEFORMITIES - ACCURACY OF 3-DIMENSIONAL RECONSTRUCTION [J].
HEMMY, DC ;
TESSIER, PL .
RADIOLOGY, 1985, 157 (01) :113-116
[6]   TEMPORAL BONE - 3-DIMENSIONAL CT .2. PATHOLOGICAL ALTERATIONS [J].
HOWARD, JD ;
ELSTER, AD ;
MAY, JS .
RADIOLOGY, 1990, 177 (02) :427-430
[7]   TEMPORAL BONE - 3-DIMENSIONAL CT .1. NORMAL ANATOMY, TECHNIQUES, AND LIMITATIONS [J].
HOWARD, JD ;
ELSTER, AD ;
MAY, JS .
RADIOLOGY, 1990, 177 (02) :421-425
[8]   CAN COMPUTED-TOMOGRAPHY BE RELIED UPON TO DETECT SKULL FRACTURES [J].
MACPHERSON, P ;
TEASDALE, E .
CLINICAL RADIOLOGY, 1989, 40 (01) :22-24
[9]   CRANIOSYNOSTOSIS - IMAGE QUALITY, CONFIDENCE, AND CORRECTNESS IN DIAGNOSIS [J].
PILGRAM, TK ;
VANNIER, MW ;
HILDEBOLT, CF ;
MARSH, JL ;
MCALISTER, WH ;
SHACKELFORD, GD ;
OFFUTT, CJ ;
KNAPP, RH .
RADIOLOGY, 1989, 173 (03) :675-679
[10]  
UHRMEISTER P, 1991, AKTUEL TRAUMATOL, V21, P675