LUMINANCE EFFECTS ON VISUAL-ACUITY AND SMALL LETTER CONTRAST SENSITIVITY

被引:43
作者
RABIN, J
机构
[1] Aircrew Health and Performance Division, U.S. Army Aeromedical Research Laboratory, Fort Rucker, AL
关键词
VISUAL ACUITY; CONTRAST SENSITIVITY; LUMINANCE; RESOLUTION;
D O I
10.1097/00006324-199411000-00003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to evaluate the effects of luminance on visual acuity (VA) and small letter contrast sensitivity (SLCS). Computer-generated letter charts were used to measure VA and SLCS [6/7.5 (20/25) Snellen equivalent] as a function of stimulus luminance. Letter size (VA) and contrast (SLCS) were varied in equal logarithmic steps, making the task and scoring procedure comparable for the two types of measurement. Both VA and SLCS decreased with decreasing luminance, but the effect was far greater in the contrast domain. Reducing luminance from 116 cd/m2 to 0.23 cd/m2 produced a 3 x reduction in VA, but a 17 x reduction in SLCS. The greater sensitivity of SLCS to luminance endured even after correction for greater measurement variability. SLCS is a sensitive approach for detecting resolution loss undisclosed by standard measures of VA. It may be useful for monitoring visual loss from light attenuation in early cataracts, and for detecting subtle resolution loss from neural or pathologic factors in ocular and neuro-ophthalmologic disease.
引用
收藏
页码:685 / 688
页数:4
相关论文
共 14 条
[1]  
Shlaer S., The relation between visual acuity and illumination, J Gen Physiol, 21, pp. 165-188, (1937)
[2]  
Sheedy J.E., Bailey I.L., Raasch T.W., Visual acuity and chart luminance, Am J Optom Physiol Opt, 61, pp. 595-600, (1984)
[3]  
Brown A.M., Dobson V., Maler J., Visual acuity of human infants at scotopic, mesopic and photopic luminances, Vision Res, 27, pp. 1845-1858, (1987)
[4]  
Coletta N.J., Clark H.K., Change in foveal acuity with light level: Optical factors. Ophthalmic Vis Optics/Nonlnvasive Assess Vis Sys, Tech Dig Ser (Vol, 3, (1993)
[5]  
De Valois R.L., Morgan H., Snodderly D.M., Psychophysical studies of the monkey vision III. Spatial luminance contrast sensitivity tests of macaque and human observers, Vision Res, 14, pp. 75-81, (1974)
[6]  
Kelly D.H., Visual contrast sensitivity, Optica Acta, 24, pp. 107-129, (1977)
[7]  
Banks M.S., Geisler W.S., Bennett P.J., The physical limits of grating visibility, Vision Res, 27, pp. 1915-1924, (1987)
[8]  
Sues F.E., Uvijls A., Contrast sensitivity in retinitis pigmentosa at different luminance levels, Clin Vis Scl, 7, pp. 147-151, (1992)
[9]  
Kelly D.H., Visual responses to time-dependent stimuli. I. Amplitude sensitivity measurements, J Opt Soc Am, 51, pp. 422-429, (1961)
[10]  
Rabin J., Optical defocus: Differential effects on size and contrast letter recognition thresholds, Invest Ophthalmol Vis Sci, 35, pp. 646-648, (1994)