AUTOMATED GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY ASSAY FOR TEBUFELONE AND A C-13, O-18-LABELED ANALOG IN PLASMA - APPLICABILITY TO ABSOLUTE BIOAVAILABILITY DETERMINATION

被引:14
作者
DOBSON, RLM
KELM, GR
NEAL, DM
机构
[1] Procter & Gamble Pharmaceuticals, Miami Valley Laboratories, The Procter & Gamble Company, Cincinnati, Ohio, 45239-8707
[2] It Corporation, Cincinnati, Ohio, 45246
关键词
D O I
10.1002/bms.1200230206
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An automated capillary gas chromatography/tandem mass spectrometry (GC/MS/MS) assay for the simultaneous quantitation of tebufelone (TE) and C-13,O-18-labeled TE (TE-CO) in plasma was developed. This method permits the use of stable isotope coadministration (TE and TE-CO dosed concurrently via peroral and intravenous routes, respectively) for the determination of TE absolute bioavailability. The selectivity of MS/MS conducted on a triple-quadrupole instrument allowed minimal sample preparation and rapid analysis. Electron ionization produced molecular ions (M(+.)) for TE, TE-CO, and the 3-methyl-TE internal standard, which were selected in Q1 to undergo collisionally activated dissociation in Q2. Quantitation was achieved through monitoring product ions at m/z 248, 251, and 248, respectively, in Q3. A 2-1000 ng per sample (40 pg to 20 ng injected) quantitation range provided access to an effective 1-5000 p.p.b. plasma concentration range (0.2-2 g samples) for both TE and TE-CO. The assay showed no bias and less than 8% relative standard deviation over the entire range. The method was used to determine plasma levels of TE and TE-CO in four dogs receiving 2.5:2.5 mg/kg TE:TE-CO, intravenously. The pharmacokinetics of both isotopomers proved to be identical, indicating no isotope effect and verifying the chemical stability of the O-18-carbonyl label under these dosing conditions. In addition, the applicability of this analytical approach to the determination of TE peroral bioavailability was initially tested in dogs.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 11 条
[1]  
BAILLIE TA, 1981, PHARMACOL REV, V33, P81
[2]   STABLE ISOTOPES IN CLINICAL PHARMACOKINETIC INVESTIGATIONS - ADVANTAGES AND DISADVANTAGES [J].
BROWNE, TR .
CLINICAL PHARMACOKINETICS, 1990, 18 (06) :423-433
[3]   LONG-TERM PERFORMANCE OF A GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY ASSAY FOR TEBUFELONE IN PLASMA [J].
DOBSON, RLM ;
NEAL, DM ;
DEMARK, BR ;
WARD, SR .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1819-1824
[4]   ABSOLUTE BIOAVAILABILITY OF CARBAMAZEPINE AFTER ORAL-ADMINISTRATION OF A 2-PERCENT SYRUP [J].
GERARDIN, A ;
DUBOIS, JP ;
MOPPERT, J ;
GELLER, L .
EPILEPSIA, 1990, 31 (03) :334-338
[5]   THE APPLICATION OF STABLE ISOTOPES IN BIOMEDICAL-RESEARCH [J].
HASKINS, NJ .
BIOMEDICAL MASS SPECTROMETRY, 1982, 9 (07) :269-277
[6]   DETERMINATION OF TEBUFELONE (A NEW ANTIINFLAMMATORY DRUG) STRENGTH AND STABILITY IN BULK DRUG, DOSAGE FORMULATIONS AND FEED ADMIXTURES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KAFFENBERGER, RM ;
EICHHOLD, TH ;
DOYLE, MJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 505 (02) :349-356
[7]   BIOAVAILABILITY DETERMINATION OF LIDOCAINE BY CAPILLARY GAS-CHROMATOGRAPHY AMMONIA CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
KARLAGANIS, G ;
BIRCHER, J .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (09) :513-516
[8]   SYNTHESIS AND BACK EXCHANGE OF O-18 LABELED AMINO-ACIDS FOR USE AS INTERNAL STANDARDS WITH MASS-SPECTROMETRY [J].
MURPHY, RC ;
CLAY, KL .
BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (07) :309-314
[9]   ISOTOPE EFFECTS - DEFINITIONS AND CONSEQUENCES FOR PHARMACOLOGICAL STUDIES [J].
VANLANGENHOVE, A .
JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 26 (06) :383-389
[10]   SYMMETRICAL CONFIDENCE-INTERVALS FOR BIOEQUIVALENCE TRIALS [J].
WESTLAKE, WJ .
BIOMETRICS, 1976, 32 (04) :741-744