CONTROL OF MICROBIAL ACTIVITY BY FLOW-INJECTION ANALYSIS DURING HIGH CELL-DENSITY CULTIVATION OF ESCHERICHIA-COLI

被引:13
作者
DING, T
BILITEWSKI, U
SCHMID, RD
KORZ, DJ
SANDERS, EA
机构
[1] GESELL BIOTECHNOL FORSCH GMBH, DEPT ENZYME TECHNOL & NAT CHEM, AG BIOSENSOREN, MASCHERODER WEG 1, W-3300 BRAUNSCHWEIG, GERMANY
[2] GESELL BIOTECHNOL FORSCH GMBH, DEPT BIOCHEM ENGN, W-3300 BRAUNSCHWEIG, GERMANY
关键词
HIGH CELL DENSITY CULTIVATION; FLOW INJECTION ANALYSIS; BIOELECTROCHEMICAL; MEDIATOR; ONLINE BIOPROCESS CONTROL; BIOMASS ACTIVITY;
D O I
10.1016/0168-1656(93)90104-U
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The application of an automated flow injection analysis (FIA) system for on-line determination of microbial activity, during high cell density cultivations of Escherichia coli is reported. Based on a bioelectrochemical principle, the FIA method used a redox mediator (potassium hexacyanoferrate(III)) to facilitate electron transfer from the microorganisms to an electrochemical detector. Assays were carried out using a new sampling device which provided aseptic operation by use of a valve and chemical sterilisation. No sample dilution or pretreatment was necessary for biomass concentrations up to approx. 40 g l-1. The sample volume was 0.5 ml and the overall analysis time was 5 min. FIA signals were found to correlate well with the oxygen uptake rate (OUR). Changes in metabolic activity due to low substrate levels or high inhibitor concentrations in the cultivation medium became obvious from the FIA signals.
引用
收藏
页码:143 / 157
页数:15
相关论文
共 33 条
  • [1] A CHEMICALLY STERILIZABLE BARRIER FOR THE PROTECTION OF FERMENTERS DURING AUTOMATIC SAMPLING INTO A FLOW-INJECTION SYSTEM
    APPELQVIST, R
    JOHANSSON, G
    HOLST, O
    MATTIASSON, B
    [J]. ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) : 299 - 306
  • [2] CALORIMETRIC INVESTIGATION OF AEROBIC FERMENTATIONS
    BIROU, B
    MARISON, IW
    VONSTOCKAR, U
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (05) : 650 - 660
  • [3] RAPID-DETERMINATION OF THE GLUCOSE CONTENT OF MOLASSES USING A BIOSENSOR
    BRADLEY, J
    KIDD, AJ
    ANDERSON, PA
    DEAR, AM
    ASHBY, RE
    TURNER, APF
    [J]. ANALYST, 1989, 114 (03) : 375 - 379
  • [4] BROOKS SL, 1987, BIOSENSORS, V3, P45
  • [5] IMPROVED OLIGONUCLEOTIDE SITE-DIRECTED MUTAGENESIS USING M13 VECTORS
    CARTER, P
    BEDOUELLE, H
    WINTER, G
    [J]. NUCLEIC ACIDS RESEARCH, 1985, 13 (12) : 4431 - 4443
  • [6] DELANEY GM, 1984, J CHEM TECH BIOT B, V34, P13
  • [7] RAPID-DETERMINATION OF MICROORGANISMS USING A FLOW-INJECTION SYSTEM
    DING, T
    SCHMID, RD
    [J]. ANALYTICA CHIMICA ACTA, 1990, 234 (01) : 247 - 251
  • [8] DING T, 1992, THESIS TU MUNCHEN
  • [9] ONLINE DETERMINATION OF LACTIC-ACID DURING KEFIR FERMENTATION BASED ON A FIBEROPTIC LACTIC-ACID BIOSENSOR AND FLOW-INJECTION ANALYSIS
    DREMEL, BAA
    YANG, W
    SCHMID, RD
    [J]. ANALYTICA CHIMICA ACTA, 1990, 234 (01) : 107 - 112
  • [10] EMDE R, 1990, THESIS U TUBINGEN