BACTERIAL-CONTAMINATION OF AIR AND SURGICAL WOUNDS DURING JOINT REPLACEMENT OPERATIONS - COMPARISON OF 2 DIFFERENT TYPES OF STAFF CLOTHING

被引:22
作者
SCHEIBEL, JH
JENSEN, I
PEDERSEN, S
机构
[1] Department of Clinical Microbiology, Copenhagen County Hospitals
关键词
SURGICAL CLOTHING; WOUND SAMPLING; BACTERIAL CONTAMINATION; JOINT REPLACEMENT;
D O I
10.1016/0195-6701(91)90220-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Compared with conventional surgical clothing, polypropylene coveralls reduced the bacterial contamination of the air of a conventionally ventilated operating room by 62%. The contamination of surgical wounds during joint replacement was also reduced, but not to a significant degree. Sixteen percent of the bacteria sampled from the wounds were resistant to the prophylactic antibiotic and the importance of a clean air system for performing joint replacement operations is stressed. The use of commercially available non-woven swabs for sampling bacteria from the surgical wound compared favourably with the use of specially prepared velvet pads. © 1991.