IMPROVED TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT PATENCY WITH PTFE-COVERED STENT-GRAFTS - EXPERIMENTAL RESULTS IN SWINE

被引:114
作者
NISHIMINE, K
SAXON, RR
KICHIKAWA, K
MENDELHARTVIG, J
TIMMERMANS, HA
SHIM, HJ
UCHIDA, BT
BARTON, RE
KELLER, FS
ROSCH, J
机构
[1] OREGON HLTH SCI UNIV,SOTTER INTERVENT INST,PORTLAND,OR 97201
[2] NARA MED UNIV,DEPT RADIOL,NARA,JAPAN
[3] NARA MED UNIV,DEPT ONCORADIOL,NARA,JAPAN
[4] CHUNG ANG UNIV,DEPT RADIOL,SEOUL 156756,SOUTH KOREA
关键词
LIVER; INTERVENTIONAL PROCEDURE; SHUNTS; PORTOSYSTEMIC; STENTS AND PROSTHESES;
D O I
10.1148/radiology.196.2.7617843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the ability of stent-grafts made with polytetrafluoroethylene (PTFE) graft material to improve transjugular intrahepatic portosystemic shunt (TIPS) patency. MATERIALS AND METHODS: TIPS were created in 13 swine by using PTFE-covered stent-grafts. Uncovered TIPS were placed in 13 other swine. Twenty-one of 26 animals were followed up with portal venography for 3 months or until the shunt became severely stenotic. Five animals without severe stenosis were sacrificed before 3 months because of illness. RESULTS: At 4 weeks after TIPS placement, nine of 13 stent-graft TIPS were patent (<50% diameter narrowing) compared with only one patent stent in 13 uncovered TIPS. Six of 13 stent-graft TIPS remained patent until the animals were sacrificed. In 11 of 12 uncovered TIPS, stenosis was most prominent in the parenchymal tract. In five of seven stent-graft TIPS, stenosis was most prominent in the hepatic vein above the end of the graft material. Bile leaks were discovered in six occluded uncovered TIPS and in two of the stent-graft TIPS. CONCLUSION: PTFE-covered stent-grafts significantly improved TIPS patency in swine (P < .01). However, stenosis in the hepatic vein led to late shunt malfunction in selected cases.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 21 条
  • [11] High occlusion rate in experimental transjugular intrahepatic portosystemic shunt created with a Dacron-covered nitinol stent
    Otal, P
    Rousseau, H
    Vinel, JP
    Ducoin, H
    Hassissene, S
    Joffre, F
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (02) : 183 - 188
  • [12] Primary implantation of polyester-covered stent-grafts for transjugular intrahepatic portosystemic stent shunts (TIPSS): A pilot study
    Manfred Cejna
    Siegfried Thurnher
    Johann Pidlich
    Klaus Kaserer
    Maria Schoder
    Johannes Lammer
    CardioVascular and Interventional Radiology, 1999, 22 : 305 - 310
  • [13] Intravascular US-guided direct intrahepatic portacaval shunt with a PTFE-covered stent-graft: Feasibility study in swine and initial clinical results
    Petersen, B
    Uchida, BT
    Timmermans, H
    Keller, FS
    Rosch, J
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (04) : 475 - 486
  • [14] Improved patency of transjugular intrahepatic portosystemic shunt: The efficacy of cilostazol for the prevention of pseudointimal hyperplasia in swine TIPS models
    Park, Sang Woo
    Cha, In Ho
    Kim, Chul Hwan
    Jeon, Hae Jeong
    Park, Jeong Hee
    Hong, Suk Joo
    Lee, In Sik
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (04) : 719 - 724
  • [15] Improved Patency of Transjugular Intrahepatic Portosystemic Shunt: The Efficacy of Cilostazol for the Prevention of Pseudointimal Hyperplasia in Swine TIPS Models
    Sang Woo Park
    In Ho Cha
    Chul Hwan Kim
    Hae Jeong Jeon
    Jeong Hee Park
    Suk Joo Hong
    In Sik Lee
    CardioVascular and Interventional Radiology, 2007, 30 : 719 - 724
  • [16] Transjugular intrahepatic portosystemic shunt:: Evaluation of the impact of the Stent's configuration on the patency rate
    Schaefer, P. J.
    Jahnike, T.
    Schaefer, F. K.
    Hedderich, J.
    Hinrichsen, H.
    Heller, M.
    Mueller-Huelsbeck, S.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 965 - 970
  • [17] Polytetrafluoroethylene-covered nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation: 3-year experience
    Rossi, P
    Salvatori, FM
    Fanelli, F
    Bezzi, M
    Rossi, M
    Marcelli, G
    Pepino, D
    Riggio, O
    Passariello, R
    RADIOLOGY, 2004, 231 (03) : 820 - 830
  • [18] PTFE-encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: Experimental evaluation
    Haskal, ZJ
    Davis, A
    McAllister, A
    Furth, EE
    RADIOLOGY, 1997, 205 (03) : 682 - 688
  • [19] Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: An experimental study in a swine model
    Seo, TS
    Oh, JH
    Park, YK
    Song, HY
    Park, SJ
    Yuk, SH
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (04) : 241 - 247
  • [20] Transjugular intrahepatic portosystemic shunt with the Strecker stent for control of refractory acute and chronic variceal bleeding - Results in 50 patients
    Canizares, RB
    RodriguezLaiz, JM
    Martin, MC
    Belda, AE
    Alonso, FC
    Roldan, AFP
    Castro, LS
    Arregui, EC
    Ricote, GC
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1996, 31 (03) : 285 - 293