RAPID DYNAMIC CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE LIVER AND PORTAL-VEIN

被引:23
作者
WARD, J
MARTINEZ, D
CHALMERS, AG
RIDGWAY, J
ROBINSON, PJ
SMITH, MA
机构
[1] GEN INFIRM,DEPT RADIOL,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
[2] GEN INFIRM,DEPT MED PHYS,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
关键词
D O I
10.1259/0007-1285-66-783-214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was firstly to show the diagnostic value of a rapid acquisition multislice sequence (TurboFLASH) during bolus injection of gadolinium-DTPA by comparing it with the pulse sequences currently used for abdominal studies and secondly to develop improved scanning protocols for the liver. Patients were referred for upper abdominal studies including portal vein assessment. 40 patients were imaged in the coronal plane using a multislice TurboFLASH (TF) sequence (TR = 100; TE = 4) acquired during a breath-hold period of 19 s. The short echo time allows up to 11 slices of 5 mm thickness to bc acquired simultaneously. Images were obtained before, during and after bolus administration of Gd-DTPA. The slices from each acquisition were combined using a maximum intensity projection algorithm to include all the vessels on a single image. Initially each patient was scanned using a conventional axial T2 weighted spin-echo sequence (T2W-SE) (TR2000; TE = 45/90) and a coronal T1 weighted spin-echo sequence (TR450; TE = 15). The clarity of the demonstration of vascular anatomy was compared and scored for ail sequences by two radiologists. Vessel patency, the conspicuity of mass lesions and the spread of tumour to adjacent structures were also scored. The anatomy of the main portal vein was significantly better shown by coronal TF images after bolus injection than on T2W-SE images or TF before Gd-DTPA. The right and left portal veins were equally well shown by coronal TF with Gd-DTPA and T2W-SE images. There was no significant difference between contrast enhanced TF and T2W-SE imaging in visualization of the hepatic veins. More lesions were demonstrated by post-contrast TF than by T2W-SE imaging. Portal venous occlusion was better appreciated by post-contrast TF. Our results demonstrate that Gd-DTPA TF imaging improves visualization of the main portal vein compared with SE sequences and provides a more accurate assessment of vessel patency. The segmental anatomy of the liver is better appreciated and the demonstration of focal liver lesions compared with T2W-SE images is improved during the non-equilibrium phase of enhancement. TF acquisitions before and after Gd-DTPA are obtained in approximately 5 min; thus a marked reduction in examination time can be achieved.
引用
收藏
页码:214 / 222
页数:9
相关论文
共 18 条
  • [1] CHIEN D, 1991, Magnetic Resonance Quarterly, V7, P31
  • [2] DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS
    EDELMAN, RR
    SIEGEL, JB
    SINGER, A
    DUPUIS, K
    LONGMAID, HE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) : 1213 - 1219
  • [3] MR ANGIOGRAPHY AND DYNAMIC FLOW EVALUATION OF THE PORTAL VENOUS SYSTEM
    EDELMAN, RR
    ZHAO, B
    LIU, C
    WENTZ, KU
    MATTLE, HP
    FINN, JP
    MCARDLE, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 755 - 760
  • [4] HEPATIC VASCULAR ANATOMY ON MAGNETIC-RESONANCE IMAGING
    FISHER, MR
    WALL, SD
    HRICAK, H
    MCCARTHY, S
    KERLAN, RK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) : 739 - 746
  • [5] IMPROVING MR IMAGE QUALITY IN THE PRESENCE OF MOTION BY USING REPHASING GRADIENTS
    HAACKE, EM
    LENZ, GW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) : 1251 - 1258
  • [6] HAAG K, 1991, VASCULAR IMAGING COL, P241
  • [7] CONVENTIONAL AND RAPID MR IMAGING OF THE LIVER WITH GD-DTPA
    HAMM, B
    WOLF, KJ
    FELIX, R
    [J]. RADIOLOGY, 1987, 164 (02) : 313 - 320
  • [8] DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING
    HEIKEN, JP
    WEYMAN, PJ
    LEE, JKT
    BALFE, DM
    PICUS, D
    BRUNT, EM
    FLYE, MW
    [J]. RADIOLOGY, 1989, 171 (01) : 47 - 51
  • [9] MR ANGIOGRAPHY IN PORTAL-HYPERTENSION - DETECTION OF VARICES AND IMAGING TECHNIQUES
    JOHNSON, CD
    EHMAN, RL
    RAKELA, J
    ILSTRUP, DM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 578 - 584
  • [10] GRADIENT ECHO MRI OF PORTAL-VEIN THROMBOSIS
    MARTINOLI, C
    CITTADINI, G
    PASTORINO, C
    ROLLANDI, G
    DERCHI, LE
    GROZIO, G
    GARLASCHI, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (02) : 226 - 234