THERMOLUMINESCENT RESPONSE OF LIF-MG,TI (TLD-100) AS A FUNCTION OF IRRADIATION TEMPERATURE FOR VARIOUS TYPES OF RADIATION

被引:0
|
作者
KITIS, G
CHARALAMBOUS, S
TUYN, JWN
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermoluminescent (TL) response of LiF:Mg,Ti (TLD-100) as a function of irradiation temperature (T(irr)) was studied for different types of radiation such as Co-60 gamma rays, Am-241 gamma rays, positive pions (pi+) and moderated PuBe neutrons. It was found that the TL response increases as the T(irr) rises up to 120-degrees-C and then decreases in a manner which is LET dependent.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 50 条
  • [1] DOSE DEPENDENCE OF RADIATION INDUCED DAMAGE IN THE THERMOLUMINESCENT RESPONSE OF LIF:Mg,Ti (TLD-100)
    Reshes, G.
    Biderman, S.
    Horowitz, Y. S.
    Oster, L.
    Eliyahu, I.
    Ginsburg, D.
    Shapiro, A.
    Assor, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 232 - 237
  • [2] FIELD APPLICATION OF LIF-MG,CU,P (GR200A) AND LIF-MG,TI (TLD-100) THERMOLUMINESCENT MATERIALS IN ENVIRONMENTAL DOSIMETRY
    BRAI, M
    PUCCIO, P
    BARTOLOTTA, A
    FERRARA, G
    HAUSER, S
    RIZZO, S
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (02) : 107 - 111
  • [3] OPTICAL BLEACHING OF DEFECT CENTERS IN TLD-100 (LIF-MG, TI)
    MERKLIN, JF
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (03): : 519 - 523
  • [4] OPTICALLY INDUCED DICHROISM OF Z2-CENTERS IN LIF-MG, TI (TLD-100)
    JEN, LC
    MERKLIN, JF
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1978, 50 (02): : 469 - 474
  • [5] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [6] COMPUTERIZED GLOW CURVE DECONVOLUTION APPLIED TO THE ANALYSIS OF THE KINETICS OF PEAK 5 IN LIF-MG,TI (TLD-100)
    YOSSIAN, D
    HOROWITZ, YS
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (07) : 1495 - 1508
  • [7] Dependence of sensitisation of LiF:Mg,Ti (TLD-100) on the partial readout end temperature
    Piters, TM
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    Perez, R
    Aceves, R
    BarbozaFlores, M
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 207 - 210
  • [8] Some dosimetric characteristics of the high temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 203 - 207
  • [9] Dose response of F center optical absorption in LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2014, 71 : 237 - 241
  • [10] TL RESPONSE OF LIF TLD-100 AT HIGH IRRADIATION TEMPERATURES
    KATHURIA, SP
    SUNTA, CM
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1982, 70 (02): : K125 - K128