SPECIFIC ASSAY FOR ENDOTOXIN USING IMMOBILIZED HISTIDINE, LIMULUS AMEBOCYTE LYSATE AND A CHROMOGENIC SUBSTRATE

被引:9
|
作者
NAWATA, M
MINOBE, S
HASE, M
WATANABE, T
SATO, T
TOSA, T
机构
[1] Research Laboratory of Applied Biochemistry, Tanabe Seiyaku Co., Ltd., Yodogawa-ku, Osaka, 532
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 597卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80139-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Limulus amoebocyte lysate (LAL) test is inhibited or enhanced by many substances. In order to overcome this problem, a specific endotoxin assay method using a membrane filter unit, a chromogenic LAL reagent, and immobilized histidine (which is a specific adsorbent for endotoxins) was developed. Endotoxins are quantitatively adsorbed on immobilized histidine. The adsorbed endotoxins are separated from LAL-inhibiting or -enhancing substances by the membrane filter unit, and their activities are directly assayed with the LAL reagent in a filter cup without any inhibition or enhancement. The reproducibility and the accuracy of this method are high. This new endotoxin assay method using immobilized histidine can be used for the determination of endotoxins in a solution containing LAL-inhibiting or -enhancing substances such as amino acids and antibiotics, as an alternative to the more common gel-clot technique.
引用
收藏
页码:415 / 424
页数:10
相关论文
共 50 条
  • [41] Heparin enables the reliable detection of endotoxin in human serum samples using the Limulus amebocyte lysate assay
    Stephan Harm
    Claudia Schildböck
    Denisa Cont
    Viktoria Weber
    Scientific Reports, 14 (1)
  • [42] Utilization of a chromogenic Limulus amebocyte lysate blood assay in a multi-center study of sepsis
    Ketchum, PA
    Parsonnet, J
    Stotts, LS
    Novitsky, TJ
    Schlain, B
    Bates, DW
    JOURNAL OF ENDOTOXIN RESEARCH, 1997, 4 (01): : 9 - 16
  • [43] REMOVAL OF ENDOTOXIN (PYROGEN) FROM ERYTHROPOIETIN BY LIMULUS AMEBOCYTE LYSATE
    SIEGEL, SE
    SHORE, N
    ORTEGA, J
    DUKES, PP
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 608 - 608
  • [44] Selective assay for LPS with polylysine-immobilized cellulose beads and limulus amebocyte lysate
    Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555, Japan
    不详
    e-J. Surf. Sci. Nanotechnol., (747-749):
  • [45] Selective Assay for LPS with Polylysine-Immobilized Cellulose Beads and Limulus Amebocyte Lysate
    Sakata, Masayo
    Fukuma, Yuriko
    Kunitake, Masashi
    Todokoro, Masami
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2009, 7 : 747 - 749
  • [46] Human endothelial cell-based assay for endotoxin as sensitive as the conventional Limulus Amebocyte Lysate assay
    Unger, Ronald E.
    Peters, Kirsten
    Sartoris, Anne
    Freese, Christian
    Kirkpatrick, C. James
    BIOMATERIALS, 2014, 35 (10) : 3180 - 3187
  • [47] A quartz crystal microbalance sensor for endotoxin assay by monitoring limulus amebocyte lysate protease reaction
    Liu, Tao
    Zhang, Wei
    Zhou, Lianqun
    Guo, Zhen
    Tang, Yuguo
    Miao, Peng
    ANALYTICA CHIMICA ACTA, 2017, 961 : 106 - 111
  • [48] THE LIMULUS AMEBOCYTE LYSATE ASSAY FOR BACTERIAL-ENDOTOXINS
    MCCARTNEY, AC
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 1986, 13 (03): : 180 - 192
  • [49] Optimization and Influence Mechanism of Sampling and Analysis of Airborne Endotoxin Based on Limulus Amebocyte Lysate Assay
    Wen, Nuanjia
    Liu, Hang
    Fu, Yan
    Wang, Can
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (04) : 1000 - 1010
  • [50] NEW, SENSITIVE ROCKET IMMUNOELECTROPHORETIC ASSAY FOR MEASUREMENT OF THE REACTION BETWEEN ENDOTOXIN AND LIMULUS AMEBOCYTE LYSATE
    BAEK, L
    JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 17 (06) : 1013 - 1020