Optimal radiation beam profiles considering the stochastic process of patient positioning in fractionated radiation therapy

被引:57
|
作者
Lof, J [1 ]
Lind, BK [1 ]
Brahme, A [1 ]
机构
[1] UNIV STOCKHOLM,S-17176 STOCKHOLM,SWEDEN
关键词
D O I
10.1088/0266-5611/11/6/005
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
We present a solution to the problem of finding optimal beam profiles in fractionated radiation therapy when taking the uncertainty in beam patient alignment into account. The problem was previously solved for the special cases of one single dose fraction and infinitely many fractions. For few fractions (less than or equal to 5), symmetry considerations reduce the problem so that it can be handled with ordinary numerical integration techniques. For the general case, including the frequently used 20-30 fractions, a Monte Carlo integration method has been developed. As may be expected, a linear response model for radiation sensitivity, based only on the total dose delivered, is insufficient for a large number of dose fractions with sharp beam edges. Under such circumstances the full linear quadratic model for cell survival has to be incorporated. The standard technique of opening up the fields to compensate for the positioning uncertainty is only feasible when the surrounding normal tissues tolerate radiation well. The present studies indicate that the probability of achieving tumour control without inducing severe injury to normal tissue can be increased if optimal non-uniform beams are used.
引用
收藏
页码:1189 / 1209
页数:21
相关论文
共 50 条
  • [1] OPTIMAL RADIATION BEAM PROFILES CONSIDERING UNCERTAINTIES IN BEAM PATIENT ALIGNMENT
    LIND, BK
    KALLMAN, P
    SUNDELIN, B
    BRAHME, A
    ACTA ONCOLOGICA, 1993, 32 (03) : 331 - 342
  • [2] Ultrasound for patient positioning in radiation therapy
    Willoughby, T
    Kupelian, P
    Weinhous, M
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 517 - 517
  • [3] Coordinate transformations and positioning uncertainties for fractionated stereotactic radiation therapy
    Li, S
    Williams, JA
    Wharam, MD
    Jackson, J
    Myers, L
    Dectorie, N
    RADIOLOGY, 1998, 209P : 397 - 397
  • [4] Centre internal retrospective evaluation of patient positioning in stereotactic fractionated radiation therapy of intracranial tumours
    Wehrle, J.
    Kuechler, S.
    Grosu, A. -L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 81 - 82
  • [5] Biologically Optimized Online Patient Positioning for Prostate External Beam Radiation Therapy
    Huang, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S166 - S166
  • [6] Optimal beam quality for Linac-based Spatially Fractionated Grid Radiation Therapy (SFGRT)
    Liang, L.
    Bekerat, H.
    Tomic, N.
    Vuong, F. DeBlois T.
    Devic, S.
    Nobah, A.
    Mohiuddin, M.
    Moftah, B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S385 - S386
  • [7] Multistage stochastic fractionated intensity modulated radiation therapy planning
    Bodur, Merve
    Cevik, Mucahit
    Cire, Andre A.
    Ruschin, Mark
    Wang, Juyoung
    COMPUTERS & OPERATIONS RESEARCH, 2023, 160
  • [8] Patient positioning and immobilisation for advanced radiation therapy
    Mullaney, L.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S556 - S556
  • [9] PRECISION IN PATIENT POSITIONING IN RADIATION-THERAPY
    KHAN, FM
    MEDICAL PHYSICS, 1984, 11 (03) : 417 - 417
  • [10] Patient Positioning by Online Adaptive Radiation Therapy
    Farace, Paolo